English   español  
Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/22613
Compartir / Impacto:
Estadísticas
Add this article to your Mendeley library MendeleyBASE
Citado 2 veces en Web of Knowledge®  |  Ver citas en Google académico
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Título

How the method of choice to assess liquid crystal tunable filters’bandpass function impacts the spectroradiometric measurements performed with them

AutorPeralta, Celia; Pons Aglio, Alicia ; Campos Acosta, Joaquín
Palabras claveLiquid crystal tunable filter
Bandpass function
Multispectral imaging
Fecha de publicación25-nov-2009
EditorInstitute of Physics Publishing
CitaciónJournal of Optics 12: 015707(2010)
ResumenMultispectral imaging systems and techniques have become powerful tools for the rapid measurement of high-spatial-resolution spectral images. Liquid crystal tunable filters (LCTF)attached to a monochrome CCD camera are being widely used as spectral analysis systems in different applications, particularly in colour imaging. Among these applications is the measurement of the spectral radiance profile of inhomogeneous sources. In such a system, uncertainty and resolution of the effective spectral distribution of the source mainly depend on that of the system’s responsivity as well as on that of the LCTF bandpass function. In the present work, the bandpass function of a liquid crystal tunable filter has been determined, using both the indirect method and the direct one. It has been demonstrated that the results yielded by either method are not equivalent, which implies that, when the bandpass function needs to be known with low uncertainty, this curve has to be measured by means of the direct method. Not only does the indirect method yield an erroneous bandpass function, but it also provides a different relation between the band’s central wavelength and the nominal wavelength. The effective radiance values that are obtained based on the direct method’s bandpass function can be up to 5% higher or 4% lower than those obtained from the indirect method’s bandpass function. The spectral variation of this discrepancy is oscillating, showing a higher amplitude for the lower wavelengths. This fact can make the measurement errors to be rather large for those radiation sources having narrow spectral distributions, such as lasers or LEDs.
Versión del editorhttp://stacks.iop.org/JOpt/12/015707
URIhttp://hdl.handle.net/10261/22613
DOI10.1088/2040-8978/12/1/015707
Aparece en las colecciones: (IFA) Artículos
Ficheros en este ítem:
No hay ficheros asociados a este ítem.
Mostrar el registro completo
 



NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.