English   español  
Please use this identifier to cite or link to this item: http://hdl.handle.net/10261/221901
Share/Impact:
Statistics
logo share SHARE   Add this article to your Mendeley library MendeleyBASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE
Exportar a otros formatos:

Title

Belle II pixel detector: Performance of final DEPFET modules

AuthorsPaschen, B.; Boronat Arévalo, Marçà ; Esperante Pereira, Daniel ; Fuster, Juan ; Gomis, P.; Lacasta Llácer, Carlos ; Moya, David ; Sánchez, J. G.; Vila, Iván ; Virto, A. L.; Vos, Marcel
KeywordsBelle II
DEPFET
PXD
Issue Date2020
PublisherElsevier
CitationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 958: 162222 (2020)
AbstractA DEpleted P-channel Field Effect Transistor (DEPFET) based pixel detector was developed for the Belle II VerteX Detector (VXD). It is designed to achieve a good impact parameter resolution better than 15𝜇m at the very high luminosity conditions of this experiment. In the first half of 2018 four final production modules have been deployed in the commissioning run of the detector and their performance is discussed.
DescriptionBelle-II DEPFET and PXD Collaboration: et al.
Publisher version (URL)https://doi.org/10.1016/j.nima.2019.05.063
URIhttp://hdl.handle.net/10261/221901
ISSN0168-9002
10.1016/j.nima.2019.05.063
Appears in Collections:(IFIC) Artículos
(IFCA) Artículos
Files in This Item:
File Description SizeFormat 
accesoRestringido.pdf59,24 kBAdobe PDFThumbnail