Determination of aluminium, titanium, niobium and vanadium in low-alloyed steels by spark ablation coupled with inductively coupled plasma atomic emission spectrometry

AuthorsGómez Coedo, Aurora CSIC ; Dorado López, María Teresa CSIC ; Jiménez Seco, José L.; Gutiérrez Cobo, Isabel
Issue Date1992
PublisherRoyal Society of Chemistry (UK)
CitationJournal of Analytical Atomic Spectrometry 7: 11-14 (1992)
AbstractA medium-voltage spark at a high repetition rate, coupled with excitation in an argon inductively coupled plasma (ICP) was applied to the direct determination of Al, Ti, Nb and V in low-alloyed steels. Tests were conducted using Bureau of Analysed Samples reference materials, series 451/1-455/1 and 456/1-460/1. A comparative evaluation of the analytical performances obtained with spark optical emission spectrometry, ICP with pneumatic nebulization and spark ablation inductively coupled plasma atomic emission spectrometry is given. The analytical parameters evaluated are the limit of detection, signal to background ratio, background equivalent concentration and relative standard deviation.
Publisher version (URL)http://dx.doi.org/10.1039/JA9920700011
URIhttp://hdl.handle.net/10261/221634
DOI10.1039/JA9920700011
Identifiersdoi: 10.1039/JA9920700011
issn:: 0267-9477
Appears in Collections:(CENIM) Artículos

Files in This Item:
File Description SizeFormat
accesoRestringido.pdf15,38 kBAdobe PDFThumbnail
View/Open
Show full item record
Review this work

WEB OF SCIENCETM
Citations

16
checked on May 17, 2022

Page view(s)

87
checked on May 22, 2022

Download(s)

12
checked on May 22, 2022

Google ScholarTM

Check

Altmetric

Dimensions


WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.