Título

Depth profile analysis of copper coating on steel using laser ablation inductively coupled plasma mass spectrometry

AutorGómez Coedo, Aurora CSIC ; Dorado López, María Teresa CSIC ; Padilla, Isabel CSIC ORCID ; Fariñas, Juan C. CSIC
Fecha de publicación2005
EditorRoyal Society of Chemistry (UK)
CitaciónJournal of Analytical Atomic Spectrometry 20: 612-620 (2005)
ResumenA commercial highly focused (Gaussian) nanosecond UV (266 nm) Nd:YAG laser ablation system coupled to an inductively coupled plasma quadrupole mass spectrometer was examined as a tool for depth profile analysis of copper coating on steel. The studied samples were Standard Reference Materials 1361b and 1362b from NIST, which consist of a set of eight coupons of an AISI 1010 cold rolled sheet steel substrate with a uniform coating of copper (certified copper coating thickness: 5.9, 12.3, 25.3, 40.6, 52.0, 77, 130, and 199 ?m). Depth resolution was determined from the normalized depth profiles as a function of irradiance, which was varied by changing the laser pulse energy and the focusing conditions, as well as coating thickness. At lower irradiances, depth resolution values were higher for irradiances obtained by changing the laser pulse energy, whereas at higher irradiances this parameter was higher for irradiances obtained by changing the focusing conditions. At moderate irradiance levels, the results obtained were quite similar, and, in addition, the best depth resolution was attained in this irradiance range, which was obtained by using a moderate laser energy (about 2 mJ per pulse) and by focusing the laser beam below the sample surface (approximately 2000 ?m). Depth resolution increased linearly with coating thickness. For the eight studied samples the ablation rate was approximately 1 ?m per pulse and the depth resolution values were between 0.8 ?m for the thinnest coating and 26 ?m for the thickest one.
Versión del editorhttp://dx.doi.org/10.1039/b504114g
URIhttp://hdl.handle.net/10261/221632
DOI10.1039/b504114g
Identificadoresdoi: 10.1039/b504114g
issn:: 0267-9477
Aparece en las colecciones: (CENIM) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Depth_profile.pdf829,32 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

22
checked on 18-abr-2024

WEB OF SCIENCETM
Citations

21
checked on 24-feb-2024

Page view(s)

132
checked on 19-abr-2024

Download(s)

216
checked on 19-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


Este item está licenciado bajo una Licencia Creative Commons Creative Commons