Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/215814
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

MEGARA optics: Sub-aperture stitching interferometry for large surfaces

AutorAguirre-Aguirre, Daniel; Carrasco, Esperanza; Izazaga-Pérez, Rafael; Páez, Gonzalo; Granados-Agustín, Fermín; Percino-Zacarías, Elizabeth; Gil de Paz, Armando; Gallego, Jesús; Iglesias-Páramo, J. CSIC ORCID; Villalobos-Mendoza, Brenda
Palabras claveInstrumentation: spectrographs
Techniques: image processing
Instrumentation: miscellaneous
Fecha de publicación2018
EditorIOP Publishing
CitaciónPublications of the Astronomical Society of the Pacific 130(986): 045001 (2018)
ResumenIn this work, we present a detailed analysis of sub-aperture interferogram stitching software to test circular and elliptical clear apertures with diameters and long axes up to 272 and 180 mm, respectively, from the Multi-Espectrógrafo en GTC de Alta Resolución para Astronomía (MEGARA). MEGARA is a new spectrograph for the Gran Telescopio Canarias (GTC). It offers a resolution between 6000 and 20000 via the use of volume phase holographic gratings. It has an integral field unit and a set of robots for multi-object spectroscopy at the telescope focal plane. The output end of the fibers forms the spectrograph pseudo-slit. The fixed geometry of the collimator and camera configuration requires prisms in addition to the flat windows of the volume phase holographic gratings. There are 73 optical elements of large aperture and high precision manufactured in Mexico at the Instituto Nacional de Astrofísica, Óptica y Electrónica (INAOE) and the Centro de Investigaciones en Óptica (CIO). The principle of stitching interferometry is to divide the surface being tested into overlapping small sections, which allows an easier analysis (Kim & Wyant 1981). This capability is ideal for non-contact tests for unique and large optics as required by astronomical instruments. We show that the results obtained with our sub-aperture stitching algorithm were consistent with other methods that analyze the entire aperture. We used this method to analyze the 24 MEGARA prisms that could not be tested otherwise. The instrument has been successfully commissioned at GTC in all the spectral configurations. The fulfillment of the irregularity specifications was one of the necessary conditions to comply with the spectral requirements.© 2018. The Astronomical Society of the Pacific. All rights reserved.
Versión del editorhttp://dx.doi.org/10.1088/1538-3873/aaa6b1
URIhttp://hdl.handle.net/10261/215814
DOI10.1088/1538-3873/aaa6b1
Identificadoresdoi: 10.1088/1538-3873/aaa6b1
issn: 0004-6280
Aparece en las colecciones: (IAA) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

2
checked on 18-abr-2024

WEB OF SCIENCETM
Citations

2
checked on 24-feb-2024

Page view(s)

99
checked on 23-abr-2024

Download(s)

23
checked on 23-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.