English   español  
Please use this identifier to cite or link to this item: http://hdl.handle.net/10261/211899
Share/Impact:
Statistics
logo share SHARE   Add this article to your Mendeley library MendeleyBASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Exportar a otros formatos:

Title

Comportamiento a fatiga resonante en compresión de hormigones reciclados para uso estructural

Other TitlesBehavior to resonant fatigue in compression of recycled concrete for structural use
AuthorsYoris, Adrián; Thomas, Carlos; Medina, César; Polanco, Juan A.; Sánchez de Rojas, María Isabel; Frías, Moisés
KeywordsRecycled concrete
Fatigue
Resonance
Locati
Issue Date2018
Citation7th Euro-American Congress on Construction Pathology, Rehabilitation Technology and Heritage Managament (2018)
Abstract[ES]: En el presente trabajo se evalúan las propiedades físicas y mecánicas de distintos tipos de hormigones elaborados con cemento comercial y con áridos gruesos naturales y reciclados. Para tal fin se elaboraron probetas cilíndricas con distintas dosificaciones: un hormigón patrón con cemento comercial y áridos naturales, y dos hormigones con cemento comercial y áridos reciclados con 25% y 50% de reemplazo. De los hormigones elaborados se determinaron la densidad, porosidad, absorción, resistencia a compresión simple, módulo de elasticidad y comportamiento a fatiga resonante en compresión. Para llevar adelante este último ensayo se aplicó la metodología Locati, para lo cual se configuraron 6 escalones de 1·105 ciclos cada uno, con una tensión mínima única y una tensión máxima creciente para cada uno de los escalones. Los resultados obtenidos muestran que hay una pérdida de capacidad de carga significativa en todos los hormigones evaluados, independientemente de su tipo. Por otra parte, se observa una pérdida de rigidez elevada en el hormigón patrón, en tanto que en los hormigones con áridos reciclados dicha pérdida es significativamente menor.
[EN]: In the present work, the physical and mechanical properties of different types of concretes made with commercial cement and with natural and recycled coarse aggregates are evaluated. For this purpose, cylindrical specimens with different dosages were made: a standard concrete with commercial cement and natural aggregates, and two concretes with commercial cement and recycled aggregates with 25% and 50% replacement. The density, porosity, absorption, resistance to simple compression, modulus of elasticity and behavior to resonant fatigue in compression were determined from the processed concretes. To carry out this last test, the Locati methodology was applied, for which 6 steps of 1·105 cycles each were configured, with a single minimum voltage and an increasing maximum voltage for each of the steps. The results obtained show that there is a significant loss of load capacity in all the concretes evaluated, regardless of their type. On the other hand, a high loss of rigidity is observed in the standard concrete, while in the concretes with recycled aggregates said loss is significantly lower
DescriptionResumen del trabajo presentado al 7th Euro-American Congress on Construction Pathology, Rehabilitation Technology and Heritage Managament (REHABEND), celebrado en Cáceres (España) del 15 al 18 de mayo de 2018.
URIhttp://hdl.handle.net/10261/211899
Appears in Collections:(IETCC) Comunicaciones congresos
Files in This Item:
File Description SizeFormat 
behaviuse.pdf45,22 kBAdobe PDFThumbnail
View/Open
Show full item record
Review this work
 


WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.