English   español  
Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/21154
Compartir / Impacto:
Estadísticas
Add this article to your Mendeley library MendeleyBASE
Citado 79 veces en Web of Knowledge®  |  Ver citas en Google académico
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Título

Optical distortion correction in Optical Coherence Tomography for quantitative ocular anterior segment by three-dimensional imaging

AutorOrtiz, Sergio ; Siedlecki, Damian; Grulkowski, Ireneusz; Remón, Laura; Pascual, Daniel ; Wojtkowski, Maciej; Marcos, Susana
Fecha de publicación26-ene-2010
EditorOptical Society of America
CitaciónOptics Express 18(3): 2782-2796 (2010)
ResumenA method for three-dimensional 3-D optical distortion (refraction) correction on anterior segment Optical Coherence Tomography (OCT) images has been developed. The method consists of 3-D ray tracing through the different surfaces, following denoising, segmentation of the surfaces, Delaunay representation of the surfaces, and application of fan distortion correction. The correction has been applied theoretically to realistic computer eye models, and experimentally to OCT images of: an artificial eye with a Polymethyl Methacrylate (PMMA) cornea and an intraocular lens (IOL), an enucleated porcine eye, and a human eye in vivo obtained from two OCT laboratory set-ups (time domain and spectral). Data are analyzed in terms of surface radii of curvature and asphericity. Comparisons are established between the reference values for the surfaces (nominal values in the computer model; non-contact profilometric measurements for the artificial eye; Scheimpflug imaging for the real eyes in vivo and vitro). The results from the OCT data were analyzed following the conventional approach of dividing the optical path by the refractive index, after application of 2-D optical correction, and 3-D optical correction (in all cases after fan distortion correction). The application of 3-D optical distortion correction increased significantly both the accuracy of the radius of curvature estimates and particularly asphericity of the surfaces, with respect to conventional methods of OCT image analysis. We found that the discrepancies of the radii of curvature estimates from 3-D optical distortion corrected OCT images are less than 1% with respect to nominal values. Optical distortion correction in 3-D is critical for quantitative analysis of OCT anterior segment imaging, and allows accurate topography of the internal surfaces of the eye.
Versión del editorhttp://dx.doi.org/10.1364/OE.18.002782
URIhttp://hdl.handle.net/10261/21154
DOI10.1364/OE.18.002782
ISSN1094-4087
Aparece en las colecciones: (CFMAC-IO) Artículos
Ficheros en este ítem:
No hay ficheros asociados a este ítem.
Mostrar el registro completo
 



NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.