dc.description.abstractIt is commonly mentioned that corrosion of steel in presstressed concrete can induce brittle failure. It is also understood that in order to estimate the presstressed structures service life is necessary to study the pitting factor that compares the maximum corrosion pit depth with the section loss by homogeneous corrosion. Results are presented on corrosion tests to measure the corrosion depth in tendons in contact with water. In present paper, a statistical analysis has been carried out in order to obtain the pitting factor for different cross sections submerged in water. The results indicate that the pitting factor value varies between 1.20 and 1.85 depending on the confidence interval considered, which can significantly reduce the service life of the presstressed tendons as long as the exposure conditions are those set out in this study.es_ES
dc.language.isoenges_ES
dc.publisherFrontiers Mediaes_ES
dc.relation.isversionofPublisher's versiones_ES
dc.rightsopenAccesses_ES
dc.subjectCorrosiones_ES
dc.subjectPittinges_ES
dc.subjectTendones_ES
dc.subjectFailurees_ES
dc.titleExperimental and statistical analysis of the corrosion in tendons in contact with wateres_ES
dc.typeartículoes_ES
dc.identifier.doi10.3389/fmats.2019.00167-
dc.description.peerreviewedPeer reviewedes_ES
dc.relation.publisherversionhttps://doi.org/10.3389/fmats.2019.00167es_ES
dc.identifier.e-issn2296-8016-
dc.rights.licensehttp://creativecommons.org/licenses/by/4.0/es_ES
dc.relation.csices_ES
oprm.item.hasRevisionno ko 0 false*
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es_ES
item.languageiso639-1en-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.openairetypeartículo-
Aparece en las colecciones: (IETCC) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato
experimenwater.pdf713,49 kBAdobe PDFVista previa
Visualizar/Abrir
Show simple item record

CORE Recommender

SCOPUSTM   
Citations

9
checked on 11-abr-2024

WEB OF SCIENCETM
Citations

9
checked on 24-feb-2024

Page view(s)

102
checked on 23-abr-2024

Download(s)

126
checked on 23-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


Este item está licenciado bajo una Licencia Creative Commons Creative Commons