Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/208891
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorATLAS Collaboration-
dc.contributor.authorÁlvarez Piqueras, D.-
dc.contributor.authorAparisi Pozo, J.A.-
dc.contributor.authorBailey, A.J.-
dc.contributor.authorBarranco, Laura-
dc.contributor.authorCabrera, Susana-
dc.contributor.authorCastillo, F.L.-
dc.contributor.authorCastillo Mª Victoria-
dc.contributor.authorCerda Alberich, L.-
dc.contributor.authorCosta, María José-
dc.contributor.authorEscobar, Carlos-
dc.contributor.authorEstrada, Oscar-
dc.contributor.authorFerrer, Antonio-
dc.contributor.authorFiorini, L.-
dc.contributor.authorFullana, Esteban-
dc.contributor.authorFuster, Juan-
dc.contributor.authorGarcía García, Carmen-
dc.contributor.authorGarcía Navarro, José Enrique-
dc.contributor.authorGonzález de la Hoz, Santiago-
dc.contributor.authorGuerrero Rojas, J.G.R.-
dc.contributor.authorGonzalvo Rodríguez, Galo Rafael-
dc.contributor.authorHigón, Emilio-
dc.contributor.authorJimenez Pena, Javier-
dc.contributor.authorLacasta Llácer, Carlos-
dc.contributor.authorLozano Bahilo, José J.-
dc.contributor.authorMadaffari, Daniele-
dc.contributor.authorMamuzic, Judita-
dc.contributor.authorMartí García, Salvador-
dc.contributor.authorMelini, Davide-
dc.contributor.authorMiñano Moya, M.-
dc.contributor.authorMitsou, Vasiliki A.-
dc.contributor.authorRodriguez Bosca, S.-
dc.contributor.authorRodriguez Rodriguez, D.-
dc.contributor.authorRuiz Martínez, Arantxa-
dc.contributor.authorSalt, José-
dc.contributor.authorSantra, A.-
dc.contributor.authorSánchez Martínez, Javier-
dc.contributor.authorSoldevila, Urmila-
dc.contributor.authorValero, Alberto-
dc.contributor.authorValls Ferrer, Juan Antonio-
dc.contributor.authorVos, Marcel-
dc.date.accessioned2020-04-23T17:25:28Z-
dc.date.available2020-04-23T17:25:28Z-
dc.date.issued2019-09-
dc.identifierdoi: 10.1088/1748-0221/14/09/P09011-
dc.identifierissn: 1748-0221-
dc.identifier.citationJournal of Instrumentation 14: P09011 (2019)-
dc.identifier.urihttp://hdl.handle.net/10261/208891-
dc.description.abstractThe momentum measurement capability of the ATLAS muon spectrometer relies fundamentally on the intrinsic single-hit spatial resolution of the monitored drift tube precision tracking chambers. Optimal resolution is achieved with a dedicated calibration program that addresses the specific operating conditions of the 354 000 high-pressure drift tubes in the spectrometer. The calibrations consist of a set of timing offsets and drift time to drift distance transfer relations, and result in chamber resolution functions. This paper describes novel algorithms to obtain precision calibrations from data collected by ATLAS in LHC Run 2 and from a gas monitoring chamber, deployed in a dedicated gas facility. The algorithm output consists of a pair of correction constants per chamber which are applied to baseline calibrations, and determined to be valid for the entire ATLAS Run 2. The final single-hit spatial resolution, averaged over 1172 monitored drift tube chambers, is 81.7 ± 2.2 μm.-
dc.languageeng-
dc.publisherIOP Publishing-
dc.relationinfo:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/FPA2016-75141-C2-1-R-
dc.relationinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PGC2018-094856-B-100-
dc.relationinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RTI2018-094270-B-100-
dc.relationinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RTI2018-100863-B-100-
dc.relation.isversionofPublisher's version-
dc.rightsopenAccess-
dc.subjectGaseous detectors-
dc.subjectMuon spectrometers-
dc.subjectParticle tracking detectors (Gaseous detectors)-
dc.subjectWire chambers (MWPC, Thin-gap chambers, drift chambers, drift tubes, proportional chambers etc)-
dc.titleResolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2-
dc.typeartículo-
dc.identifier.doi10.1088/1748-0221/14/09/P09011-
dc.relation.publisherversionhttp://dx.doi.org/10.1088/1748-0221/14/09/P09011-
dc.date.updated2020-04-23T17:25:29Z-
dc.rights.licensehttps://creativecommons.org/licenses/by/3.0/-
dc.contributor.funderMinisterio de Economía y Competitividad (España)-
dc.contributor.funderMinisterio de Ciencia, Innovación y Universidades (España)-
dc.relation.csic-
dc.identifier.funderhttp://dx.doi.org/10.13039/501100003329es_ES
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es_ES
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextWith Fulltext-
item.cerifentitytypePublications-
item.openairetypeartículo-
item.grantfulltextopen-
Aparece en las colecciones: (IFIC) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato
364_Atlas_Resolution.pdf1,16 MBAdobe PDFVista previa
Visualizar/Abrir
Show simple item record

CORE Recommender

SCOPUSTM   
Citations

4
checked on 06-abr-2024

WEB OF SCIENCETM
Citations

1
checked on 25-feb-2024

Page view(s)

134
checked on 17-abr-2024

Download(s)

105
checked on 17-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


Este item está licenciado bajo una Licencia Creative Commons Creative Commons