Please use this identifier to cite or link to this item: http://hdl.handle.net/10261/208381
Share/Export:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE
Title

Densitometric Radiographic Imaging With Contour Sensors

AuthorsAlbiol Colomer, Francisco CSIC ORCID ; Corbi Bellot, Alberto; Albiol Colomer, Alberto
KeywordsConventional X-ray imaging
contour data
densitometric images
dynamic range
depth information
Issue DateJan-2019
PublisherInstitute of Electrical and Electronics Engineers
CitationIEEE Access 7: 18902- 18914 (2019)
AbstractWe present the technical/physical foundations of a new imaging technique that combines ordinary radiographic information (generated by conventional X-ray settings) with the patient's volume to derive densitometric images. Traditionally, these images provide quantitative information about tissues densities. In our approach, they graphically enhance either soft or bony regions. After measuring the patient's volume with contour recognition devices, the physical traversed lengths within it (as the Roentgen beam intersects the patient) are calculated and pixel-wise associated with the original radiograph (X). In order to derive this map of lengths (L), the camera equations of the X-ray system and the contour sensor are determined. The patient's surface is also translated to the point-of-view of the X-ray beam and all its entrance/exit points are sought with the help of ray-casting methods. The derived L is applied to X as a physical operation (subtraction), obtaining soft tissue(D S ) or bone-enhanced (D' B ) figures. In the D S type, the contained graphical information can be linearly mapped to the average electronic density (traversed by the X-ray beam). This feature represents an interesting proof-of-concept of associating density data to radiographs, but most important, their intensity histogram is objectively compressed, i.e., the dynamic range is more shrunk (compared against the corresponding X). This leads to other advantages: improvement in the visibility of border/edge areas (high gradient), extended manual window level/width manipulations during screening, and immediate correction of underexposed X instances. In the D' B type, high-density elements are highlighted and easier to discern. All these results can be achieved with low-energy beam exposures, saving costs and dose. Future work will deepen this clinical side of our research. In contrast with other image-based modifiers, the proposed method is grounded on the measurement of a physical entity: the span...
Publisher version (URL)http://dx.doi.org/10.1109/ACCESS.2019.2895925
URIhttp://hdl.handle.net/10261/208381
DOI10.1109/ACCESS.2019.2895925
Identifiersdoi: 10.1109/ACCESS.2019.2895925
issn: 2169-3536
Appears in Collections:(IFIC) Artículos

Files in This Item:
File Description SizeFormat
336_Densiometric_Albiol.pdf3,51 MBAdobe PDFThumbnail
View/Open
Show full item record
Review this work

Page view(s)

167
checked on Jan 26, 2022

Download(s)

84
checked on Jan 26, 2022

Google ScholarTM

Check

Altmetric

Dimensions


WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.