Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/19911
COMPARTIR / EXPORTAR:
SHARE CORE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Rodríguez Hidalgo, M. C. | - |
dc.contributor.author | Rodríguez Aumente, P. | - |
dc.contributor.author | Izquierdo, M. | - |
dc.contributor.author | Lecuona Neumann, Antonio | - |
dc.contributor.author | Salgado Manguala, R. | - |
dc.date.accessioned | 2010-01-08T12:14:22Z | - |
dc.date.available | 2010-01-08T12:14:22Z | - |
dc.date.issued | 2008-10 | - |
dc.identifier.citation | Applied Thermal Engineering 28(14-15): 1734-1744 (2008) | en_US |
dc.identifier.issn | 1359-4311 | - |
dc.identifier.uri | http://hdl.handle.net/10261/19911 | - |
dc.description.abstract | Air conditioning (AC) is spreading in Spain, where summer weather reaches temperatures above 35 °C. This causes the increase, not only of electricity consumption, but also organic refrigerant leakage due to the use of vapour-compression machines. An experimental research on solar absorption cooling has been carried out at Universidad Carlos III de Madrid (UC3M) in order to evaluate alternative lower impact AC techniques. The facility is based on an on-Campus field of 50 m2 flat plate solar collectors driving a single-effect commercial LiBr/H2O absorption machine through a hot-water storage tank. Experimental operating parameters have been recorded during 2004 summer season in periods of 10 min showing all the relevant figures of merit. Results show that absorption machine cooling power reaches 6–10 kW, with a generator driving power input of 10–15 kW, achieving a mean cooling period of 6.5 h of complete solar autonomy on a seasonal average day. In order to measure the market applicability of this setup, the instantaneous thermal load and demand of a single detached housing of total floorspace of 90 m2 were calculated using standard techniques. Its peak ranged from 6 to 8 kW. Seasonal solar fraction of AC provided by the facility reached 56%. This work shows results on system performance, economic investing, energy and economic savings and includes environmental impact reduction, when comparing the solar absorption system with a conventional vapour-compression machine. A sensitivity study to solar field size has been performed to yield the reasonable share of the absorption machine in the seasonal cooling demand. The result indicates that the dimensioning of the facility is correct. | en_US |
dc.description.sponsorship | This work has been partially funded by the Spanish government research grant M. C. y T. CLIMABCAR project DPI 2003-01567, ENE 2005-08255-CO2-01 and MINICOM project (FIT 0204-2004-68 and FIT 020100-2003-233), Project UC3M-IME-05-011 by the Local Government of Madrid. Their contribution is greatly appreciated. | en_US |
dc.format.extent | 98816 bytes | - |
dc.format.mimetype | application/vnd.ms-excel | - |
dc.language.iso | eng | en_US |
dc.publisher | Elsevier | en_US |
dc.rights | closedAccess | en_US |
dc.subject | Solar energy | en_US |
dc.subject | Absorption cooling | en_US |
dc.subject | Environmental impact reduction | en_US |
dc.subject | Solar air conditioning | en_US |
dc.subject | Energy saving | en_US |
dc.subject | Sustainability | en_US |
dc.title | Energy and carbon emission savings in Spanish housing air-conditioning using solar driven absorption system | en_US |
dc.type | artículo | en_US |
dc.identifier.doi | 10.1016/j.applthermaleng.2007.11.013 | - |
dc.description.peerreviewed | Peer reviewed | en_US |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.applthermaleng.2007.11.013 | en_US |
dc.type.coar | http://purl.org/coar/resource_type/c_6501 | es_ES |
item.openairetype | artículo | - |
item.grantfulltext | none | - |
item.cerifentitytype | Publications | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | No Fulltext | - |
item.languageiso639-1 | en | - |
Aparece en las colecciones: | (IETCC) Artículos |
CORE Recommender
SCOPUSTM
Citations
78
checked on 11-abr-2024
WEB OF SCIENCETM
Citations
69
checked on 14-feb-2024
Page view(s)
365
checked on 18-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.