English
español
Please use this identifier to cite or link to this item:
http://hdl.handle.net/10261/19899
Share/Impact:
Statistics |
![]() ![]() ![]() |
|
|
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |||
|
Title: | Multivariate resolution of roeluted peaks in hyphenated liquid chromatography - linear sweep voltammetry |
Authors: | Berbel, Francisco; Kapoya, Elisabeth; Díaz-Cruz, José Manuel; Ariño, Cristina; Esteban, Miquel; Tauler, Romà ![]() |
Keywords: | Liquid chromatography Voltammetric detection Linear sweep voltammetry Coeluted peaks Multivariate analysis |
Issue Date: | 30-Apr-2003 |
Publisher: | Wiley-Blackwell |
Citation: | Electroanalysis 15(5-6): 499-508 (2003) |
Abstract: | A novel application of Multivariate Curve Resolution with Alternating Least Squares (MCR-ALS) method for the background correction and for the resolution and quantitation of coeluted analyte mixtures in liquid chromatography with voltammetric detection is presented. The selected voltammetric technique for analyte detection was Linear Sweep Voltammetry (LSV), which provides richer multivariate information than the more widespread employed univariate amperometric detection. Use of other voltammetric detection techniques was also attempted but they gave much poorer results because of instrumental and software limitations concerning data acquisition times. The method is tested in the resolution and quantitation of mixtures of pyrocatechol, ascorbic acid and epinephrine coeluting mixtures. In spite of the extremely large background current contributions observed using this voltammetric technique, MCR-ALS was shown to be able to model this background contribution satisfactory as well as to resolve and give good quantitative estimations of these three analyte in their mixtures. The proposed approach is recommended for resolution and quantitation of complex coeluted mixtures using liquid chromatography with voltammetric detection and also for fast initial screening of optimal potential when amperometric detection is preferred. |
Description: | 10 pages, 6 figures, 1 table. |
Publisher version (URL): | http://dx.doi.org/10.1002/elan.200390060 |
URI: | http://hdl.handle.net/10261/19899 |
DOI: | 10.1002/elan.200390060 |
ISSN: | 1040-0397 (Print) |
Appears in Collections: | (IDAEA) Artículos |
Files in This Item:
There are no files associated with this item.
Show full item record
Review this work
Review this work
Related articles:
WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.