English   español  
Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/19678
Compartir / Impacto:
Estadísticas
Add this article to your Mendeley library MendeleyBASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Título

On the prediction of optical aberrations by personalized eye models

AutorNavarro, Rafael; González, Luis M.; Hernández-Matamoros, José Luis
Fecha de publicaciónjun-2006
EditorLippincott Williams & Wilkins
CitaciónOptometry and Vision Science 83(6): 371-381 (2006)
ResumenPurpose. The purpose of this study is to develop and analyze a method to obtain optical schematic models of individual eyes. Each model should be able to reproduce the measured monochromatic wave aberration with high fidelity. Methods. First, we choose a generic eye model as the input guess and then apply a two-stage customization procedure. Stage 1 consists of replacing, in the initial generic model, those anatomic and optical parameters with experimental data measured on the eye under analysis. The set of experimental data was that provided by a standard clinical preoperative examination, namely lens topography, ultrasound biometry, and total wave aberration. Then, the second stage is to find the unknown lens structure that would reproduce the measured wave aberration through optical optimization. Two totally different initial eye models have been compared; one considers a simpler constant refractive index for the lens, whereas the second model has a gradient-index (GRIN) lens. Results. This automatic customization method has been applied to 19 eyes with different degrees of spherical ametropia (from +0.4 D to -8 D). Two models have been obtained for each eye (constant and gradient index lens). The results were highly satisfactory, with 100% convergence, and with average RMS prediction errors approximately A/100. This is one order of magnitude lower than typical measurement errors. The models with a constant refractive index lens tended to overestimate surface curvatures, whereas for the GRIN model, lens surfaces were too flat. Conclusions. The proposed method is highly efficient and robust giving a high-fidelity reproduction of the wavefront in all cases attempted so far. Limitations found in reproducing the geometry of the lens seem to be associated with the use of inaccurate models of its refractive index.
Descripción6 figures, 2 tables.-- El pdf del artículo es la versión pre-print.
Versión del editorhttp://dx.doi.org/10.1097/01.opx.0000221399.50864.c7
URIhttp://hdl.handle.net/10261/19678
DOI10.1097/01.opx.0000221399.50864.c7
ISSN1040-5488
Aparece en las colecciones: (ICMA) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
eye_modelsOVS2006.pdf552,05 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo
 


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.