Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/193942
COMPARTIR / EXPORTAR:
SHARE CORE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Título: | Experimental validations of a tunable-lens-based visual demonstrator of multifocal corrections |
Autor: | Akondi, Vyas CSIC ORCID; Sawides, L. CSIC ORCID; Marrakchi, Y.; Gambra, Enrique CSIC ORCID; Marcos, Susana CSIC ORCID ; Dorronsoro, Carlos CSIC ORCID | Fecha de publicación: | 15-nov-2018 | Editor: | Optical Society of America | Citación: | Biomedical Optics Express 9(12): 6302-6317 (2018) | Resumen: | The Simultaneous Vision simulator (SimVis) is a visual demonstrator of multifocal lens designs for prospective intraocular lens replacement surgery patients and contact lens wearers. This programmable device employs a fast tunable lens and works on the principle of temporal multiplexing. The SimVis input signal is tailored to mimic the optical quality of the multifocal lens using the theoretical SimVis temporal profile, which is evaluated from the through-focus Visual Strehl ratio metric of the multifocal lens. In this paper, for the first time, focimeter-verified on-bench validations of multifocal simulations using SimVis are presented. Two steps are identified as being critical to accurate SimVis simulations. Firstly, a new iterative approach is presented that improves the accuracy of the theoretical SimVis temporal profile for three different multifocal intraocular lens designs – diffractive trifocal, refractive segmented bifocal, and refractive extended depth of focus, while retaining a low sampling. Secondly, a fast focimeter is used to measure the step response of the tunable lens, and the input signal is corrected to include the effects of the transient behavior of the tunable lens. It was found that the root-mean-square of the difference between the estimated through-focus Visual Strehl ratio of the multifocal lens and SimVis is not greater than 0.02 for all the tested multifocal designs. | Descripción: | 16 pags., 8 figs. 2 tabs. | Versión del editor: | https://doi.org/10.1364/BOE.9.006302 | URI: | http://hdl.handle.net/10261/193942 | DOI: | 10.1364/BOE.9.006302 | Identificadores: | doi: 10.1364/BOE.9.006302 issn: 2156-7085 |
Aparece en las colecciones: | (CFMAC-IO) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
Experimental validations.pdf | 3,65 MB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
PubMed Central
Citations
6
checked on 14-abr-2024
SCOPUSTM
Citations
14
checked on 16-abr-2024
WEB OF SCIENCETM
Citations
14
checked on 29-feb-2024
Page view(s)
208
checked on 19-abr-2024
Download(s)
189
checked on 19-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
Artículos relacionados:
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.