English   español  
Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/19385
Compartir / Impacto:
Estadísticas
Add this article to your Mendeley library MendeleyBASE
Citado 16 veces en Web of Knowledge®  |  Ver citas en Google académico
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Título

Improvement approaches for the determination of Cr(VI), Cd(II), Pd(II) and Pt(IV) contained in aqueous samples by conventional XRF instrumentation

AutorFontàs, Claudia; Marguí, Eva ; Queralt Mitjans, Ignacio
Fecha de publicaciónene-2009
EditorJohn Wiley & Sons
CitaciónX-Ray Spectrom. 38: 9–17 (2008)
ResumenThis work was aimed to achieve improved instrumental sensitivity and detection limits for the determination of several elements (Cr (VI), Cd, Pd and Pt) in liquid samples by using conventional energy dispersive x-ray fluorescence (EDXRF) and wavelength dispersive x-ray fluorescence (WDXRF) instrumentation. In all cases, the preconcentration of metals from liquid solutions was performed by using membranes activated with the commercial anionic exchanger Aliquat 336 (a quaternary ammonium salt), which also permits the isolation of Cr (VI) species for further x-ray fluorescence analysis. Likewise, for the improvement of the instrumental sensitivity, a special sample holder device was used in the case of Cd determination by EDXRF (tungsten x-ray source) instrumentation. ForWDXRF analysis, the spectral evaluation was carried out by the integration of the peak area (using WinQXAS software) instead of the common net peak line intensity traditionally used in conventional WDXRF systems.With the proposed methodologies, a linear response between themetal present in the aqueous solutions and the metal extracted in the membranes was obtained, highlighting the feasibility of using these membranes as standards for x-ray fluorescence spectrometry (XRF) analysis for future determination of these elements when contained in liquid samples. Concerning the calculated detection limits, in all cases, theywere in the μg l−1 range, indicating the possibilities of the proposed methodology for trace determination content of Cd, Cr(VI), Pd and Pt in liquid solutions using conventional EDXRF andWDXRF instrumentation.
Versión del editorhttp://www3.interscience.wiley.com/journal/120750829/abstract?CRETRY=1&SRETRY=0
URIhttp://hdl.handle.net/10261/19385
DOI10.1002/xrs.1093
ISSN0049-8246 (Print)
1097-4539 (Online)
Aparece en las colecciones: (ICTJA) Artículos
Ficheros en este ítem:
No hay ficheros asociados a este ítem.
Mostrar el registro completo
 



NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.