Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/191877
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Feasibility of gas chromatography--ion trap tandem mass spectrometry for the determination of polychlorinated biphenyls in food

AutorGómara, Belén CSIC ORCID ; Fernández Martín, Mario Antonio ; González Carlos, María José CSIC ORCID ; Ramos, Lourdes CSIC ORCID
Fecha de publicación2006
EditorElsevier
CitaciónJournal of Separation Science 29(1): 123-130 (2006)
ResumenThe different parameters affecting the ionisation and fragmentation of selected polychlorinated biphenyls (PCBs) in an IT detector working in the MS/MS mode, ITD(MS/MS), have been optimised for maximum selectivity and sensibility. The low LODs (in the range 0.03–0.3 μg/L), the satisfactory repeatability (RSDs in general below 11%) and reproducibility (RSDs below 17%) obtained when analysing standard solutions ensured proper determination of the PCBs studied at the concentrations typically found in food samples. Foodstuffs naturally contaminated with varying levels of PCBs have been analysed using the optimised GC–ITD(MS/MS) method. The results obtained compared favourably with those found using more conventional detectors, such as (micro‐)electron capture detection (for ortho‐PCBs) and high‐resolution MS (for non‐ortho‐PCBs), as well as with the consensus PCB levels established for these particular samples via an international interlaboratory exercise. The relative merits of these three detectors have been discussed.
Versión del editorhttps://doi.org/10.1002/jssc.200500089
URIhttp://hdl.handle.net/10261/191877
DOI10.1002/jssc.200500089
ISSN1615-9306
E-ISSN1615-9314
Aparece en las colecciones: (IQOG) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf59,24 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

PubMed Central
Citations

1
checked on 31-mar-2024

SCOPUSTM   
Citations

26
checked on 19-abr-2024

WEB OF SCIENCETM
Citations

22
checked on 26-feb-2024

Page view(s)

201
checked on 24-abr-2024

Download(s)

31
checked on 24-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


Artículos relacionados:


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.