Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/189970
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Roughness of Deposited Carbon-Based Coatings and Its Statistical Characteristics at Nano and Microscales

AutorBorodich, Feodor M.; Brousseau, Emmanuel; Clarke, Alastair; Pepelyshev, Andrey; Sánchez-López, J.C. CSIC ORCID
Palabras claveRoughness
Normality tests
Carbon-based coatings
Nanoscale
Microscale
Fecha de publicación14-may-2019
EditorFrontiers Media
CitaciónFrontiers in Mechanical Engineering 5: 24 (2019)
ResumenTopography of surfaces may influence many processes in tribology including friction and adhesion. Its influence is usually taken into account in various statistical models of rough surfaces. Most of these models are based on an explicit or implicit assumption of normality of the asperity heights or similar assumptions that involve Gaussian distributions. Recently it has been shown that the height distribution of surfaces prepared by grinding are not Gaussian at both nano and micro-scales, while topography of epoxy resin replicas of polishing papers having nominal asperity sizes up to several micrometers, was Gaussian. Here we study roughness of carbon-based coatings deposited by direct current pulsed magnetron sputtering with and without substrate bias voltage at micro and nano-scale. Hardness measured using a Berkovich indenter tip gave 43 (biased) and 14 (non-biased) GPa, respectively. First the heights of the nano-asperities were determined by AFM (Atomic Force Microscopy). Then the heights of the micro-asperities were measured by a profilometer (a stylus). Finally the same regions measured by stylus were again studied by AFM. Standard statistical parameters of surfaces are determined at each scale. It has been also shown that the stylus measurements did not cause plastic deformations of the harder (biased) sample because the distributions of heights at nano-scale were the same. Using the experimental data obtained, the assumption of the normal distribution for the roughness heights has been studied by application of various modern tests of normality. Measurements of surfaces by stylus and by AFM with the 117 nm steps showed that the surfaces satisfy the assumption of normality of the heights. However, further studies with the 10 nm AFM steps showed that the roughness of the non-biased sample is not normal. Hence, the applicability of the standard statistical models of adhesive contact between rough solids to the non-biased sample may be questionable.
Versión del editorhttps://doi.org/10.3389/fmech.2019.00024
URIhttp://hdl.handle.net/10261/189970
DOI10.3389/fmech.2019.00024
E-ISSN2297-3079
Aparece en las colecciones: (ICMS) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
fmech-05-00024.pdf4,29 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

9
checked on 16-abr-2024

WEB OF SCIENCETM
Citations

9
checked on 18-feb-2024

Page view(s)

158
checked on 18-abr-2024

Download(s)

121
checked on 18-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


Este item está licenciado bajo una Licencia Creative Commons Creative Commons