Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/18840
COMPARTIR / EXPORTAR:
SHARE CORE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Título: | Platinum-Group Element Distribution in Some Ore Deposits: Results of EPMA and Micro-PIXE Analyses |
Autor: | Gervilla, Fernando CSIC ORCID; Cabri, Louis J.; Kojonen, Kari; Oberthür, Thomas; Weiser, Thorolf W.; Johanson, Bo; Sie, Soey H.; Campbell, J. L.; Teesdale, Williams J.; Gilles Laflamme, J. H. | Palabras clave: | Platinum-group elements Trace electron probe microanalysis Micro-PIXE Sulfides Arsenides |
Fecha de publicación: | 14-abr-2004 | Editor: | Springer Nature | Citación: | Microchimica Acta 147(3): 167-173 (2004) | Resumen: | The distribution of platinum-group elements (PGE) in the Main Sulfide Zone of the Great Dyke of Zimbabwe, in the arsenide ores of Vammala and Kylmäkoski mines in Finland, and in the chromite-Ni arsenide ores from the Ronda and Beni Bousera massifs (Spain and Morocco) has been studied by means of different optical and microanalytical techniques. The results show a bimodal distribution of PGE in the ores from the Great Dyke and the Vammala and Kylmäkoski mines where Pd, Pt and, to lesser extent, Rh occur both as discrete platinum-group minerals and in solid solution in sulfides, arsenides and sulfarsenides. In the ores from Ronda and Beni Bousera, platinum-group elements occur only in solid solution in arsenides and sulfarsenides. Trace electron probe (EPMA) and micro-PIXE analyses of Pd in sulfides, arsenides and sulfarsenides produce comparable results at concentration levels well above their limit of detection (LOD). These are 27–29thinspppm by EMPA and 2.5–7thinspppm by micro-PIXE. Whereas trace EPMA on arsenides and sulfarsenides measure Pt concentrations above 33–35thinspppm, the proximity of the Pt L lines and the As Kagr line severely degrade de detection limit for Pt in micro-PIXE analyses, increasing the LOD up to 440thinspppm. The rest of PGE were randomly detected by both methods at concentrations close to their LOD. | Descripción: | 7 pages, 3 figures, 4 tables. | Versión del editor: | http://dx.doi.org/10.1007/s00604-004-0187-5 | URI: | http://hdl.handle.net/10261/18840 | DOI: | 10.1007/s00604-004-0187-5 | ISSN: | 0001-6268 |
Aparece en las colecciones: | (IACT) Artículos |
Mostrar el registro completo
CORE Recommender
SCOPUSTM
Citations
20
checked on 17-abr-2024
WEB OF SCIENCETM
Citations
20
checked on 23-feb-2024
Page view(s)
386
checked on 22-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.