Título: | Microclimatic monitoring in an historic church fitted with modern heating: Implications for the preventive conservation of its cultural heritage |
Autor: | Varas, María José CSIC ORCID; Fort González, Rafael CSIC ORCID | Palabras clave: | Microclimatic monitoring Modern heating systems Historic church Cultural Heritage Preventive conservation |
Fecha de publicación: | nov-2018 | Editor: | Elsevier | Citación: | Building and Environment 145: 290-307 (2018) | Resumen: | Conservation of historic churches' interior artistic and architectural heritage may be severely compromised by heating systems that alter indoor microclimatic stability. The modern centralised heating systems installed over the last 20 years, are claimed to guarantee comfort without jeopardising heritage assets by warming only the lower, occupied areas. Each building is a case unto itself, however, and even in recently installed facilities where it may still be too soon to determine possible harm to the cultural heritage, a plan to monitor the microclimate and its heating-induced fluctuations must be designed to guarantee the conservation of artworks. In this case study, the impact of heating was observed to vary due to architectural differences within the building, the type of facility and daily usage patterns. Within 1 h, the church's latest generation heating system raises the air temperature in nearly the entire building, including the upper heights, to the programmed 18 ± 1 °C, while lowering the environmental relative humidity by up to 1/3. Although (Category II and III) thermal comfort is reached in 1 h, daily heating of that duration is not recommended, for it would result in short-term relative humidity values below the target relative humidity range for preventive conservation of the church's indoor heritage. The mechanical damage (fissures and cracking) that may be inflicted on these assets is related to thermal contraction-expansion and hygroscopic contraction-swelling cycles. | Versión del editor: | https://doi.org/10.1016/j.buildenv.2018.08.060 | URI: | http://hdl.handle.net/10261/185775 | DOI: | 10.1016/j.buildenv.2018.08.060 | ISSN: | 0360-1323 |
Aparece en las colecciones: | (IGEO) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
accesoRestringido.pdf | 15,38 kB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
SCOPUSTM
Citations
32
checked on 30-mar-2024
WEB OF SCIENCETM
Citations
30
checked on 12-feb-2024
Page view(s)
146
checked on 18-abr-2024
Download(s)
18
checked on 18-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.