Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/179985
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Fluorescent microarray for multiplexed quantification of environmental contaminants in seawater samples

AutorSanchís Villariz, Ana CSIC; Salvador, Juan Pablo CSIC ORCID; Campbell, Katrina; Elliott, Christopher T.; Shelver, Weilin L.; Li, Qingxiao; Marco, María Pilar CSIC ORCID CVN
Palabras claveAntibodies
Environmental analysis
Fluorescent microarray chip
Immunoassay
Multiplexed analysis
Monoclonal antibodies
Fecha de publicación1-jul-2018
EditorElsevier
CitaciónTalanta - the International Journal of Pure and Applied Analyt Chemistry 184: 499-506 (2018)
ResumenThe development of a fluorescent multiplexed microarray platform able to detect and quantify a wide variety of pollutants in seawater is reported. The microarray platform has been manufactured by spotting 6 different bioconjugate competitors and it uses a cocktail of 6 monoclonal or polyclonal antibodies raised against important families of chemical pollutants such as triazine biocide (i.e. Irgarol 1051®), sulfonamide and chloramphenicol antibiotics, polybrominated diphenyl ether flame-retardant (PBDE, i.e. BDE-47), hormone (17β-estradiol), and algae toxin (domoic acid). These contaminants were selected as model analytes, however, the platform developed has the potential to detect a broader group of compounds based on the cross-reactivity of the immunoreagents used. The microarray chip is able to simultaneously determine these families of contaminants directly in seawater samples reaching limits of detection close to the levels found in contaminated areas (Irgarol 1051® 0.19 ± 0,06 µg L−1; sulfapyridine, 0.17 ± 0.07 µg L−1; chloramphenicol, 0.11 ± 0.03 µg L−1; BDE-47, 2.71 ± 1.13 µg L−1; 17β-estradiol, 0.94 ± 0.30 µg L−1 and domoic acid, 1.71 ± 0.30 µg L−1). Performance of the multiplexed microarray chip was assessed by measuring 38 blind spiked seawater samples containing either one of these contaminants or mixtures of them. The accuracy found was very good and the coefficient of variation was < 20% in all the cases. No sample pre-treatment was necessary, and the results could be obtained in just 1 h 30 min. The microarray shows high sample throughput capabilities, being able to measure simultaneously more than 68 samples and screen them for a significant number of chemical contaminants of interest in environmental screening programs. © 2018 Elsevier B.V.
Versión del editorhttps://doi.org/10.1016/j.talanta.2018.03.036
URIhttp://hdl.handle.net/10261/179985
DOI10.1016/j.talanta.2018.03.036
Aparece en las colecciones: (IQAC) Artículos

Ficheros en este ítem:
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

14
checked on 19-abr-2024

WEB OF SCIENCETM
Citations

11
checked on 26-feb-2024

Page view(s)

197
checked on 23-abr-2024

Download(s)

72
checked on 23-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.