Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/16653
COMPARTIR / EXPORTAR:
SHARE CORE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Título: | Simultaneous multi-analyte determination of estrone, isoproturon and atrazine in natural waters by the RIver ANAlyser (RIANA), an optical immunosensor |
Autor: | Rodríguez-Mozaz, Sara; Reder, S.; López de Alda, Miren CSIC ORCID ; Gauglitz, Guenter; Barceló, Damià CSIC ORCID | Palabras clave: | Immunosensor Multi-analyte Pesticides Estrone Water |
Fecha de publicación: | 15-feb-2004 | Editor: | Elsevier | Citación: | Biosensors and Bioelectronics 19(7): 633-640 (2004) | Resumen: | In most medical and environmental applications of biosensors, only single analytes are determined. However, the monitoring of several analytes is obviously preferable in order to gather more information about the sample under analysis. In line with this, different technologies are being developed to obtain multi-analyte sensors. In this paper, an analytical method for the simultaneous determination of three different contaminants—atrazine, isoproturon, and estrone—in natural waters by using an optical immunosensor prototype, the so-called “RIver ANAlyser” (RIANA), is described. RIANA is based on a rapid solid-phase fluoroimmunoassay that takes place at an optical transducer chip. The transducer surface is chemically modified with three analytes derivatives placed in different discrete locations. The sensor surface can be regenerated thus allowing the performance of several measurements with the same transducer. Each test cycle, including one regeneration step, is accomplished in 15 min. Detection limits achieved were 0.155, 0.046, and 0.084 μg/l, for atrazine, isoproturon, and estrone, respectively. Satisfactory repetition, with relative standard deviations between 1.06 and 6.98%, was obtained. Excluding a minor non-specifical binding of the isoproturon antibodies, no cross-reactivity effects were observed. Matrix effects were significant only in the case of wastewater samples. Biosensor measurements were validated using conventional liquid chromatography-mass spectrometry. The results obtained with both techniques were in good agreement. |
Descripción: | 8 pages, 5 figures, 2 tables.-- PMID: 14709380 [PubMed].-- Available online Sep 10, 2003. | Versión del editor: | http://dx.doi.org/10.1016/S0956-5663(03)00255-0 | URI: | http://hdl.handle.net/10261/16653 | DOI: | 10.1016/S0956-5663(03)00255-0 | ISSN: | 0956-5663 | E-ISSN: | 1873-4235 |
Aparece en las colecciones: | (IDAEA) Artículos |
Mostrar el registro completo
CORE Recommender
SCOPUSTM
Citations
114
checked on 06-abr-2024
WEB OF SCIENCETM
Citations
101
checked on 26-feb-2024
Page view(s)
383
checked on 18-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.