English   español  
Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/164304
COMPARTIR / IMPACTO:
Estadísticas
logo share SHARE logo core CORE   Add this article to your Mendeley library MendeleyBASE

Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Exportar a otros formatos:
Título

Development of an integrated method of concentrationand immunodetection of bacteria

AutorEzenarro, Josune J.; Uria, Naroa; Castillo-Fernandez, Óscar; Párraga-Niño Noemí; Sabrià, Miquel; Muñoz Pascual, Francisco Javier
Palabras claveMicrofiltration membrane
Sample concentration
Immunoassay
E. coli
Pathogen detection
Fecha de publicaciónene-2018
EditorSpringer
CitaciónAnalytical and Bioanalytical Chemistry 410(1): 105-113 (2018)
ResumenThe microbial quality of water is a key aspect to avoid environmental and public health problems. The low pathogen concentration needed to produce a disease outbreak makes it essential to process large water volumes and use sensitive and specific methods such as immunoassays for its detection. In the present work, we describe the development of a device based on microfiltration membranes to integrate the concentration and the immunodetection of waterborne bacteria. A microfiltration membrane treatment protocol was designed to reduce the non-specific binding of antibodies, for which different blocking agents were tested. Thus, the proof of concept of the microbial detection system was also carried out using Escherichia coli as the bacterial pathogen model. E. coli suspensions were filtered through the membranes at 0.5 mL s−1, and the E. coli concentration measurements were made by absorbance, at 620 nm, of the resultant product of the enzymatic reaction among the horseradish peroxidase (HRP) bonded to the antibody, and the substrate 3,3′,5,5′-tetramethylbenzidine (TMB). The results showed that the homemade concentration system together with the developed membrane treatment protocol is able to detect E. coli cells with a limit of detection (LoD) of about 100 CFU in 100 mL.
Versión del editorhttp://doi.org/10.1007/s00216-017-0695-x
URIhttp://hdl.handle.net/10261/164304
DOI10.1007/s00216-017-0695-x
ISSN1618-2642
E-ISSN1618-2650
Aparece en las colecciones: (IMB-CNM) Artículos
Ficheros en este ítem:
No hay ficheros asociados a este ítem.
Mostrar el registro completo
 


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.