English   español  
Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/164277
COMPARTIR / IMPACTO:
Estadísticas
logo share SHARE logo core CORE   Add this article to your Mendeley library MendeleyBASE

Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Exportar a otros formatos:
Título

Novel impedimetric aptasensor for label-free detection of Escherichia coli O157:H7

AutorBrosel-Oliu, Sergi; Ferreira, Rubén; Uria, Naroa; Abramova, Natalia ; Gargallo, Raimundo; Muñoz Pascual, Francisco Javier; Bratov, Andrey
Palabras claveLabel-free biosensor
Impedimetric transducer
Aptamer
Three-dimensional interdigitated electrode array
E. coli O157:H7
Fecha de publicaciónfeb-2018
EditorElsevier
CitaciónSensors and Actuators B: Chemical 255(Part 3): 2988-2995 (2018)
ResumenMicrobial safety of drinking water constitutes a major concern in countries at all levels of economic development. Thus, rapid, sensitive and cost effective methods of pathogenic bacteria detection, like common Escherichia coli O157:H7, which can cause important diseases, are highly required. In this work an impedimetric transducer modified with E. coli specific aptamer is studied. To enhance the sensitivity a three-dimensional interdigitated electrode array (3D-IDEA) impedimetric transducer, in which the electrodes are separated by insulating barriers was used. In this sensor chemical reactions at the surface of the barrier provoke electrical charge redistribution which causes changes in the surface conductivity. A DNA aptamer, which recognizes specifically the outer membrane proteins of the E. coli O157:H7, was selected as the biorecognition moiety. Here we report a novel label-free impedimetric aptasensor for detection and quantification of pathogenic E. coli O157:H7 with a low detection limit, good selectivity and short detection time. The developed sensor shows a linear response (R2 = 0.977), proportional to the logarithm of bacterial concentration present in the sample, with the limit of detection (LOD) of about 102 cfu mL−1. No response of the aptasensor was registered in the presence of other bacterial strains (E. coli k12, Salmonella typhimurium, Staphylococcus aureus), which confirms the selectivity of the suggested detection method. Additionally, the methodology of the aptasensor regeneration was developed, so that the detection may be performed several times with the same sensor. Moreover, suitability of the aptasensor for bacteria detection in real samples was demonstrated with a new approach involving bacteria pre-concentration.
Versión del editorhttp://dx.doi.org/10.1016/j.snb.2017.09.121
URIhttp://hdl.handle.net/10261/164277
DOI10.1016/j.snb.2017.09.121
ISSN0925-4005
Aparece en las colecciones: (IMB-CNM) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
BIOS-S-17-02075.pdf Embargado hasta 1 de febrero de 20201,3 MBAdobe PDFVista previa
Visualizar/Abrir     Petición de una copia
Mostrar el registro completo
 

Artículos relacionados:


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.