English   español  
Please use this identifier to cite or link to this item: http://hdl.handle.net/10261/164274
Share/Impact:
Statistics
logo share SHARE logo core CORE   Add this article to your Mendeley library MendeleyBASE

Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Exportar a otros formatos:

Title

Impedimetric label-free sensor for specific bacteria endotoxin detection by surface charge registration

AuthorsBrosel-Oliu, Sergi; Galyamin, Dmitry; Abramova, Natalia ; Muñoz Pascual, Francisco Javier; Bratov, Andrey
KeywordsImpedimetric sensor
Surface charge
Interdigitated electrode array
Bacterial endotoxin
Concanavalin A
Issue Date20-Jul-2017
PublisherElsevier
CitationElectrochimica Acta 243: 142-151 (2017)
AbstractAn impedimetric sensor based on a three dimensional electrode array modified with concanavalin A (Con A) was used for label-free detection of bacterial endotoxin: lipopolysaccharide (LPS) from Escherichia coli. The transducer permits the detection of the surface charge changes due to interaction of immobilized Con A biorecognition element and LPS of E. coli in test solution. The deposition of Con A on the surface was carried out using the layer-by-layer method with polyethyleneimine (PEI) polycation as an initial layer. The sensor surface characterization by means of electrochemical impedance spectroscopy technique allowed registering variations in superficial resistance provoked by surface charge changes and is demonstrated as an effective method to monitor sensor parameters at each modification step as well as to follow Con A – LPS reaction. In order to prevent non-specific adsorption of LPS on PEI covered surface different blocking strategies were tested to achieve the specific response between Con A and LPS. Results obtained in this work clearly show that blocking with bovine serum albumin (BSA) is not sufficient to prevent non-specific interactions of PEI and to ensure the selective biorecognition of LPS by Con A. To achieve more efficient PEI blocking a new method was proposed based on consecutive deposition of Con A-glycogen-Con A layers. Sensors modified with PEI-(Con A-Gly)2-Con A multilayers are shown to be highly sensitive, selective and reproducible. Presented biosensor is able to detect bacterial LPS in a very short detection time (20 min) with 2 μg mL−1 limit of detection, which is much lower than reported for other biosensors with Con A.
Publisher version (URL)http://doi.org/10.1016/j.electacta.2017.05.060
URIhttp://hdl.handle.net/10261/164274
DOI10.1016/j.electacta.2017.05.060
ISSN0013-4686
Appears in Collections:(IMB-CNM) Artículos