Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/164068
COMPARTIR / EXPORTAR:
SHARE CORE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Akondi, Vyas | - |
dc.contributor.author | Dorronsoro, Carlos | - |
dc.contributor.author | Gambra, Enrique | - |
dc.contributor.author | Marcos, Susana | - |
dc.date.accessioned | 2018-04-24T08:42:59Z | - |
dc.date.available | 2018-04-24T08:42:59Z | - |
dc.date.issued | 2017-06-23 | - |
dc.identifier | doi: 10.1364/BOE.8.003410 | - |
dc.identifier | issn: 2156-7085 | - |
dc.identifier.citation | Biomedical Optics Express 8: 3410-3425 (2017) | - |
dc.identifier.uri | http://hdl.handle.net/10261/164068 | - |
dc.description | 16 pags., 10 figs., 1 tab. -- OCIS codes: (330.0330) Vision, color, and visual optics; (330.7327) Visual optics, ophthalmic instrumentation; (330.5370) Physiological optics; (220.1010) Aberrations (global); (220.1080) Active or adaptive optics. | - |
dc.description.abstract | Fast tunable lenses allow an effective design of a portable simultaneous vision simulator (SimVis) of multifocal corrections. A novel method of evaluating the temporal profile of a tunable lens in simulating different multifocal intraocular lenses (M-IOLs) is presented. The proposed method involves the characteristic fitting of the through-focus (TF) optical quality of the multifocal component of a given M-IOL to a linear combination of TF optical quality of monofocal lenses viable with a tunable lens. Three different types of M-IOL designs are tested, namely: segmented refractive, diffractive and refractive extended depth of focus. The metric used for the optical evaluation of the temporal profile is the visual Strehl (VS) ratio. It is shown that the time profiles generated with the VS ratio as a metric in SimVis resulted in TF VS ratio and TF simulated images that closely matched the TF VS ratio and TF simulated images predicted with the M-IOL. The effects of temporal sampling, varying pupil size, monochromatic aberrations, longitudinal chromatic aberrations and temporal dynamics on SimVis are discussed. | - |
dc.description.sponsorship | Consejería de Educación, Juventud y Deporte of Comunidad de Madrid and the People Programme (Marie Curie Actions) of the European Union’s Seventh Framework Programme (FP7/2007-2013) under REA grant agreement (n 291820); Ministerio de Economía y Competitividad (DTS16- 00127); Spanish Government Torres-Quevedo Program (PTQ-15-07432); EIT Health e.V. Grant agreement (HS-2016-SPAIN-03); ERC Grant Agreement (ERC-2011-AdC 294099); Spanish Government Grant (FIS2014-56643-R). | - |
dc.publisher | Optical Society of America | - |
dc.relation | info:eu-repo/grantAgreement/EC/FP7/291820 | - |
dc.relation | info:eu-repo/grantAgreement/EC/FP7/294099 | - |
dc.relation.isversionof | Publisher's version | - |
dc.rights | openAccess | - |
dc.title | Temporal multiplexing to simulate multifocal intraocular lenses: theoretical considerations | - |
dc.type | artículo | - |
dc.identifier.doi | 10.1364/BOE.8.003410 | - |
dc.relation.publisherversion | https://doi.org/10.1364/BOE.8.003410 | - |
dc.date.updated | 2018-04-24T08:42:59Z | - |
dc.description.version | Peer Reviewed | - |
dc.language.rfc3066 | eng | - |
dc.contributor.funder | Comunidad de Madrid | - |
dc.contributor.funder | European Commission | - |
dc.contributor.funder | Ministerio de Economía y Competitividad (España) | - |
dc.relation.csic | Sí | - |
dc.identifier.funder | http://dx.doi.org/10.13039/501100003329 | es_ES |
dc.identifier.funder | http://dx.doi.org/10.13039/501100000780 | es_ES |
dc.identifier.funder | http://dx.doi.org/10.13039/100012818 | es_ES |
dc.identifier.pmid | 28717577 | - |
dc.type.coar | http://purl.org/coar/resource_type/c_6501 | es_ES |
item.fulltext | With Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.openairetype | artículo | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
Aparece en las colecciones: | (CFMAC-IO) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
Temporal multiplexing.pdf | 3,34 MB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
PubMed Central
Citations
14
checked on 30-mar-2024
SCOPUSTM
Citations
28
checked on 15-abr-2024
WEB OF SCIENCETM
Citations
26
checked on 24-feb-2024
Page view(s)
271
checked on 23-abr-2024
Download(s)
263
checked on 23-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
Artículos relacionados:
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.