Título

Performance of Different Light Sources for the Absolute Calibration of Radiation Thermometers

AutorMartín, M. J.; Mantilla, J.M.; Campo, D. del; Hernanz, María Luisa CSIC; Pons Aglio, Alicia CSIC ORCID; Campos Acosta, Joaquín CSIC ORCID CVN
Palabras claveStandard radiation thermometer
Radiometer
Thermodynamic temperature
Uncertainty
Radiance method
Absolute radiometry
Fecha de publicación25-jul-2017
EditorSpringer Nature
CitaciónInternational Journal of Thermophysics 38: 138 (2017)
ResumenThe evolving mise en pratique for the definition of the kelvin (MeP-K) [1, 2] will, in its forthcoming edition, encourage the realization and dissemination of the thermodynamic temperature either directly (primary thermometry) or indirectly (relative primary thermometry) via fixed points with assigned reference thermodynamic temperatures. In the last years, the Centro Español de Metrología (CEM), in collaboration with the Instituto de Óptica of Consejo Superior de Investigaciones Científicas (IO-CSIC), has developed several setups for absolute calibration of standard radiation thermometers using the radiance method to allow CEM the direct dissemination of the thermodynamic temperature and the assignment of the thermodynamic temperatures to several fixed points. Different calibration facilities based on a monochromator and/or a laser and an integrating sphere have been developed to calibrate CEM’s standard radiation thermometers (KE-LP2 and KE-LP4) and filter radiometer (FIRA2). This system is based on the one described in [3] placed in IO-CSIC. Different light sources have been tried and tested for measuring absolute spectral radiance responsivity: a Xe-Hg 500 W lamp, a supercontinuum laser NKT SuperK-EXR20 and a diode laser emitting at 6473 nm with a typical maximum power of 120 mW. Their advantages and disadvantages have been studied such as sensitivity to interferences generated by the laser inside the filter, flux stability generated by the radiant sources and so forth. This paper describes the setups used, the uncertainty budgets and the results obtained for the absolute temperatures of Cu, Co-C, Pt-C and Re-C fixed points, measured with the three thermometers with central wavelengths around 650 nm.
Descripción13 pags., 6 figs., 3 tabs. -- Part of the following topical collections: TEMPMEKO 2016: Selected Papers of the 12th International Symposium on Temperature, Humidity, Moisture and Thermal Measurements in Industry and Science
Versión del editorhttps://doi.org/10.1007/s10765-017-2271-1
URIhttp://hdl.handle.net/10261/163763
DOI10.1007/s10765-017-2271-1
Identificadoresdoi: 10.1007/s10765-017-2271-1
issn: 0195-928X
Aparece en las colecciones: (CFMAC-IO) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

5
checked on 24-abr-2024

WEB OF SCIENCETM
Citations

3
checked on 28-feb-2024

Page view(s)

259
checked on 22-abr-2024

Download(s)

79
checked on 22-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.