Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/16002
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorPérez-Calatayud, J.-
dc.contributor.authorKuipers, F.-
dc.contributor.authorBallester, Facundo-
dc.contributor.authorGranero, Domingo-
dc.contributor.authorRichart, J.-
dc.contributor.authorRodríguez, Silvia-
dc.contributor.authorTormo, Alejandro-
dc.contributor.authorSantos, Manuel-
dc.date.accessioned2009-08-17T07:49:11Z-
dc.date.available2009-08-17T07:49:11Z-
dc.date.issued2008-10-22-
dc.identifier.citationRadiotherapy and Oncology 91 (2009) 181–186en_US
dc.identifier.issn0167-8140-
dc.identifier.urihttp://hdl.handle.net/10261/16002-
dc.description.abstractPurpose: According to the GYN GEC-ESTRO Recommendations, MRI is needed with the modality of T2 weighted. CT-MR compatible tandem Plus colpostats (T/C) (Nucletron) is widely used in cervical brachytherapy. The major challenge of MRI is the lack of dummy catheters. Therefore, an additional imaging modality is usually required. One disadvantage of sliced-based reconstruction is that resolution in longitudinal directions can be affected by the slice thickness. The aim of this study is to present a modified T/C applicator in which the catheter visibility is significantly improved. Methods and materials: A modification to the existing T/C applicator has been made available, increasing the catheter entrance diameter. It allows a greater dummy catheter diameter, and consequently it can be filled with more material per unit length. Visibility was studied with different materials. Results: The catheter filled with saline water plus iodine Compound was clearly seen in both axial and longitudinal acquisitions, To avoid uncertainties introduced by the slice thickness, a simple procedure is presented using longitudinal acquisitions. Conclusions: The modified applicator plus catheter allows a powerful signal in T2 weighted MRI, using a very simple and accessible material. Also, a method is proposed to solve the problem of the uncertainty derived from slice thickness using few longitudinal acquisitionsen_US
dc.description.sponsorshipThis work has been supported by Nucletron, which manufactured the applicator prototypes. This study has been supported by the Ministerio de Ciencia y Tecnología (Spain) under Projects No. FPA2007-65013-C02-01 and FPA2006-12120-C03-02. The authors would like to thank C. Kirisits, Ph.D; T. Hellenbust, Ph.D; K. Tanderup, Ph.D; and J. Pouliot, Ph.D, for the fruitful discussions and suggestions about this practical topic. The support from G. Montoliu, M.D. and C. Chatterjee, Ph.D, in the MRI settings and from C. Castro and N. Louise in the catheter’s manufacture is gratefully acknowledged.en_US
dc.format.extent22195 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.rightsclosedAccessen_US
dc.titleExclusive MRI-based tandem and colpostats reconstruction in gynaecological brachytherapy treatment planningen_US
dc.typeartículoen_US
dc.identifier.doi10.1016/j.radonc.2008.09.004-
dc.description.peerreviewedPeer revieweden_US
dc.relation.publisherversionhttp://dx.doi.org/10.1016/j.radonc.2008.09.004en_US
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es_ES
item.openairetypeartículo-
item.grantfulltextnone-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextNo Fulltext-
item.languageiso639-1en-
Aparece en las colecciones: (IFIC) Artículos
Show simple item record

CORE Recommender

SCOPUSTM   
Citations

36
checked on 16-abr-2024

WEB OF SCIENCETM
Citations

35
checked on 26-feb-2024

Page view(s)

310
checked on 23-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.