English   español  
Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/150546
COMPARTIR / IMPACTO:
Estadísticas
logo share SHARE logo core CORE   Add this article to your Mendeley library MendeleyBASE

Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Exportar a otros formatos:
Título

Predicting herbivore faecal nitrogen using a multispecies near-infrared reflectance spectroscopy calibration

AutorVillamuelas, Miriam; Serrano, Emmanuel; Espunyes, Johan; Fernández, Néstor ; López-Olvera, Jorge R. ; Garel, Mathieu; Santos, Joao; Parra-Aguado, M. Ángeles; Ramanzin, Mauricio; Fernández-Aguilar, Xavier; Colom-Cadena, Andreu; Marco, Ignasi; Lavín, Santiago; Bartolomé, Jordi ; Albanell, Elena
Fecha de publicación2017
EditorPublic Library of Science
CitaciónPLoS ONE, 12(4): e0176635 (2017)
ResumenOptimal management of free-ranging herbivores requires the accurate assessment of an animal's nutritional status. For this purpose `near-infrared reflectance spectroscopy' (NIRS) is very useful, especially when nutritional assessment is done through faecal indicators such as faecal nitrogen (FN). In order to perform an NIRS calibration, the default protocol recommends starting by generating an initial equation based on at least 50±75 samples from the given species. Although this protocol optimises prediction accuracy, it limits the use of NIRS with rare or endangered species where sample sizes are often small. To overcome this limitation we tested a single NIRS equation (i.e., multispecies calibration) to predict FN in herbivores. Firstly, we used five herbivore species with highly contrasting digestive physiologies to build monospecies and multispecies calibrations, namely horse, sheep, Pyrenean chamois, red deer and European rabbit. Secondly, the equation accuracy was evaluated by two procedures using: (1) an external validation with samples from the same species, which were not used in the calibration process; and (2) samples from different ungulate species, specifically Alpine ibex, domestic goat, European mouflon, roe deer and cattle. The multispecies equation was highly accurate in terms of the coefficient of determination for calibration R2 = 0.98, standard error of validation SECV = 0.10, standard error of external validation SEP = 0.12, ratio of performance to deviation RPD = 5.3, and range error of prediction RER = 28.4. The accuracy of the multispecies equation to predict other herbivore species was also satisfactory (R2 > 0.86, SEP < 0.27, RPD > 2.6, and RER > 8.1). Lastly, the agreement between multi- and monospecies calibrations was also confirmed by the Bland-Altman method. In conclusion, our single multispecies equation can be used as a reliable, cost-effective, easy and powerful analytical method to assess FN in a wide range of herbivore species
Versión del editorhttps://doi.org/10.1371/journal.pone.0176635
URIhttp://hdl.handle.net/10261/150546
DOI10.1371/journal.pone.0176635
Aparece en las colecciones: (EBD) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
journal.pone.0176635.pdf3,28 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo
 

Artículos relacionados:


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.