English   español  
Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/149983
COMPARTIR / IMPACTO:
Estadísticas
logo share SHARE logo core CORE   Add this article to your Mendeley library MendeleyBASE

Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Exportar a otros formatos:
Título

Comparison of samplers for the biological characterization of the sea surface microlayer

AutorAgogué, Hélène; Casamayor, Emilio O. ; Joux, Fabien; Obernosterer, Ingrid; Dupuy, Christine; Lantoine, François; Català, P.; Weinbauer, Markus G.; Reinthaler, Thomas; Herndl, Gerhard J.; Lebaron, Philippe
Fecha de publicación2004
EditorAssociation for the Sciences of Limnology and Oceanography
CitaciónLimnology and Oceanography : methods 2 : 213-225 (2004)
ResumenThe surface film of the hydrosphere covers more than 70% of the world’s surface. The sea surface microlayer (SML) or “skin” of the ocean is a sink for natural and anthropogenic material originating from the atmosphere and the water column. Organisms living in this SML are called “neuston.” Our knowledge of the biology of the SML is still in its infancy. Research of the sea surface microlayer requires the use of appropriate sampling techniques and strategies, and the question of what is the most suitable device has not yet been answered. In the present study, we have compared the efficiency of the Harvey glass plate (GP) and the Garrett metal screen (MS) to analyze a wide range of microbiological parameters in SML samples collected at two coastal stations in the NW Mediterranean Sea. Two types of membranes (Teflon and polycarbonate) were also used to collect bacterioneuston. The MS was the most appropriate technique for most biological parameters providing higher enrichment factors as compared to the GP and, therefore, the highest enrichment factors compared with underlying waters (UW). Control experiments with UW demonstrated that the enrichment reported for the MS was not biased by any selectivity of the sampler itself. Therefore, we recommend the use of the MS when the aim is to compare different biological parameters. In contrast, there is clear evidence that hydrophobic and hydrophilic membranes have an important drawback and should not be used for quantification purposes.
DescripciónEste artículo contiene 15 páginas, 3 figuras, 4 tablas.
Versión del editorhttp://dx.doi.org/10.4319/lom.2004.2.213
URIhttp://hdl.handle.net/10261/149983
DOI10.4319/lom.2004.2.213
ISSN1541-5856
Aparece en las colecciones: (CEAB) Artículos
Ficheros en este ítem:
No hay ficheros asociados a este ítem.
Mostrar el registro completo
 

Artículos relacionados:


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.