English   español  
Please use this identifier to cite or link to this item: http://hdl.handle.net/10261/149496
Share/Impact:
Statistics
logo share SHARE logo core CORE   Add this article to your Mendeley library MendeleyBASE

Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE
Exportar a otros formatos:

Title

Material properties from air puff corneal deformation by numerical simulations on model corneas

AuthorsBekesi, Nandor CSIC ORCID; Dorronsoro, Carlos CSIC ORCID; Hoz, A. de la CSIC; Marcos, Susana CSIC ORCID
Issue Date28-Oct-2016
PublisherPublic Library of Science
CitationPLoS ONE 11(10): e0165669 (2016)
AbstractObjective To validate a new method for reconstructing corneal biomechanical properties from air puff corneal deformation images using hydrogel polymer model corneas and porcine corneas. Methods Air puff deformation imaging was performed on model eyes with artificial corneas made out of three different hydrogel materials with three different thicknesses and on porcine eyes, at constant intraocular pressure of 15 mmHg. The cornea air puff deformation was modeled using finite elements, and hyperelastic material parameters were determined through inverse modeling, minimizing the difference between the simulated and the measured central deformation amplitude and central-peripheral deformation ratio parameters. Uniaxial tensile tests were performed on the model cornea materials as well as on corneal strips, and the results were compared to stress-strain simulations assuming the reconstructed material parameters. Results The measured and simulated spatial and temporal profiles of the air puff deformation tests were in good agreement (< 7% average discrepancy). The simulated stress-strain curves of the studied hydrogel corneal materials fitted well the experimental stress-strain curves from uniaxial extensiometry, particularly in the 0-0.4 range. Equivalent Young?s moduli of the reconstructed material properties from air-puff were 0.31, 0.58 and 0.48 MPa for the three polymer materials respectively which differed < 1% from those obtained from extensiometry. The simulations of the same material but different thickness resulted in similar reconstructed material properties. The air-puff reconstructed average equivalent Young?s modulus of the porcine corneas was 1.3 MPa, within 18% of that obtained from extensiometry. Conclusions Air puff corneal deformation imaging with inverse finite element modeling can retrieve material properties of model hydrogel polymer corneas and real corneas, which are in good correspondence with those obtained from uniaxial extensiometry, suggesting that this is a promising technique to retrieve quantitative corneal biomechanical properties.
Description19 págs.; 11 figs.; 2 tabs.
Publisher version (URL)https://doi.org/10.1371/journal.pone.0165669
URIhttp://hdl.handle.net/10261/149496
DOIhttp://dx.doi.org/10.1371/journal.pone.0165669
Identifiersdoi: 10.1371/journal.pone.0165669
issn: 1932-6203
Appears in Collections:(CFMAC-IO) Artículos
Files in This Item:
File Description SizeFormat 
Material.pdf2,59 MBUnknownView/Open
Show full item record
Review this work
 

Related articles:


WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.