Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/149167
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Inertial Sensor Error Reduction through Calibration and Sensor Fusion

AutorLambrecht, Stefan CSIC; Nogueira, Samuel L.; Bortole, Magdo CSIC; Siqueira, Adriano A. G.; Terra, Marco H.; Rocón, Eduardo CSIC ORCID; Pons Rovira, José Luis CSIC ORCID
Fecha de publicación17-feb-2016
EditorMultidisciplinary Digital Publishing Institute
CitaciónSensors 16 (2): 235 (2016)
ResumenThis paper presents the comparison between cooperative and local Kalman Filters (KF) for estimating the absolute segment angle, under two calibration conditions. A simplified calibration, that can be replicated in most laboratories; and a complex calibration, similar to that applied by commercial vendors. The cooperative filters use information from either all inertial sensors attached to the body, Matricial KF; or use information from the inertial sensors and the potentiometers of an exoskeleton, Markovian KF. A one minute walking trial of a subject walking with a 6-DoF exoskeleton was used to assess the absolute segment angle of the trunk, thigh, shank, and foot. The results indicate that regardless of the segment and filter applied, the more complex calibration always results in a significantly better performance compared to the simplified calibration. The interaction between filter and calibration suggests that when the quality of the calibration is unknown the Markovian KF is recommended. Applying the complex calibration, the Matricial and Markovian KF perform similarly, with average RMSE below 1.22 degrees. Cooperative KFs perform better or at least equally good as Local KF, we therefore recommend to use cooperative KFs instead of local KFs for control or analysis of walking.
Versión del editorhttps://doi.org/10.3390/s16020235
URIhttp://hdl.handle.net/10261/149167
DOI10.3390/s16020235
Identificadoresdoi: 10.3390/s16020235
Aparece en las colecciones: (IC) Artículos
(CAR) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
sensors-16-00235.pdf9,04 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

PubMed Central
Citations

4
checked on 21-abr-2024

SCOPUSTM   
Citations

16
checked on 15-abr-2024

WEB OF SCIENCETM
Citations

12
checked on 28-feb-2024

Page view(s)

258
checked on 21-abr-2024

Download(s)

418
checked on 21-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


Artículos relacionados:


Este item está licenciado bajo una Licencia Creative Commons Creative Commons