English   español  
Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/146847
COMPARTIR / IMPACTO:
Estadísticas
logo share SHARE logo core CORE   Add this article to your Mendeley library MendeleyBASE

Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Exportar a otros formatos:
Título

Chemometric evaluation of hydrophilic interaction liquid chromatography stationary phases: Resolving complex mixtures of metabolites

AutorOrtiz-Villanueva, Elena; Navarro-Reig, Meritxell; Jaumot, Joaquim; Tauler, Romà
Palabras claveAmides
Chromatographic response functions
Hydrophilic interaction liquid chromatographies
Chromatography
Fecha de publicación7-feb-2017
EditorRoyal Society of Chemistry (Great Britain)
CitaciónAnalytical Methods 9 (5): 774-785 (2017)
ResumenDifferent hydrophilic interaction liquid chromatography (HILIC) stationary phases have been evaluated using different chemometric methods with the aim of their application in metabolomics studies. Experimental factors, such as the type of HILIC stationary phase (i.e. amide, amine, zwitterionic and diol) and the mobile phase conditions (organic co-solvent, pH and ionic strength) were assessed using a full factorial experimental design. A test sample mixture of metabolites with diverse physicochemical properties (amino acids, nucleotides, nucleosides, and sugars among others) was analyzed by liquid chromatography with a diode array detector (LC-DAD) using five different HILIC columns. Application of multivariate curve resolution alternating least squares (MCR-ALS) method, allowed the full chromatographic peak resolution of all mixture constituents. This approach was particularly helpful in the case of methanol samples where the quality of the chromatographic separation (resolution) was lower in consequence of the co-solvent perturbation on the water layer formation at the surface of the stationary phase. Then, Berridge chromatographic response function (CRF), based on peak resolution, retention times and number of peaks, was used for the investigation of the best HILIC column configuration for future metabolomics studies. The best chromatographic configuration resulted in being the amide and zwitterionic HILIC stationary phases in combination with acetonitrile as organic co-solvent of the mobile phase. © 2017 The Royal Society of Chemistry.
Versión del editor10.1039/c6ay02976k
URIhttp://hdl.handle.net/10261/146847
DOI10.1039/c6ay02976k
Aparece en las colecciones: (IDAEA) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
CHEMAGEB_37.docx1,42 MBMicrosoft Word XMLVisualizar/Abrir
Mostrar el registro completo
 

Artículos relacionados:


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.