English   español  
Please use this identifier to cite or link to this item: http://hdl.handle.net/10261/14466
Share/Impact:
Statistics
logo share SHARE logo core CORE   Add this article to your Mendeley library MendeleyBASE

Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Exportar a otros formatos:
DC FieldValueLanguage
dc.contributor.authorRubio, J. C.-
dc.contributor.authorAlonso, C.-
dc.contributor.authorBurgos-Asperilla, Laura-
dc.contributor.authorGarcía-Alonso, M. C.-
dc.contributor.authorAlobera, M. A.-
dc.contributor.authorClemente, Carmen-
dc.contributor.authorMunuera, L.-
dc.contributor.authorEscudero Rincón, María Lorenza-
dc.date.accessioned2009-07-07T11:31:12Z-
dc.date.available2009-07-07T11:31:12Z-
dc.date.issued2008-06-30-
dc.identifier.citationRevista de Metalurgia 44(3): 265-272 (2008)en_US
dc.identifier.issn0034-8570-
dc.identifier.urihttp://hdl.handle.net/10261/14466-
dc.description8 pages, 6 figures and 4 tables.en_US
dc.description.abstract[ES] Se ha evaluado la respuesta ósea local, a implantes metálicos de uso endoprotésico, a distintos tiempos de evolución, desde el mes hasta los doce meses. Los tres materiales metálicos evaluados han sido una aleación de Co-Cr, cpTi, y la aleación MA 956 sobre cuya superficie se ha generado una capa de ·-alúmina, por oxidación. Los animales experimentales fueron ratas Wistard. La respuesta ósea a los materiales implantados se llevo a cabo mediante estudios histopatológicos por microscopía óptica, y la evaluación de la interfaz hueso-implante por microscopía electrónica de barrido. Se aprecia que la respuesta ósea local ante la presencia de un implante de titanio o de aleación MA 956, con capa de alúmina, fue adecuada y rápida, comenzando desde las primeras etapas, uno y tres meses, la diferenciación de tejido fibroso a tejido óseo. Esta diferenciación se ve consolidada de forma definitiva al cabo de los seis meses. Por el contrario, la respuesta del organismo ante la presencia de Co-Cr fue más lenta, de modo que a los seis meses la situación era equivalente a la de los otros implantes a los tres meses. Fue preciso esperar un año para alcanzar una situación similar entre los tres materiales estudiados.en_US
dc.description.abstract[EN] We have evaluated the local bone response to metallic implants for endoprosthetic implants, over different periods of evolution, from one month to twelve months. The three metallic materials, that have been evaluated, are an alloy of Co-Cr, cpTi, and the MA 956 alloy on whose surface, a layer ·-alumina, has been generated by oxidation. The experimental animals used were Wistard rats. The local bone response to the implanted materials, was carried out, using hispathological studies with optical microscopes and the evaluation of the bone/implant interface was studied with a scanning electron microscope (SEM). It was observed that the local bone response in the presence of an implant of titanium or of the alloy MA 956, with an alumina layer, was appropriate and rapid. The differenciation between the fibrous tissue and the bone tissue started from the first stages, at one or three months. This differentiation was definitely consolidated after six months. On the other hand, the local bone response in the presence of Co-Cr was slower, so that after six months the bone response was equivalent to that of the other implants at three months. It was necessary to wait for a year in order to reach a similar bone response among the three materials studied.en_US
dc.description.sponsorshipLos autores agradecen a la CICYT la financiación del proyecto con referencia: CTQ2005-08712-C02- 01-02/BQU.en_US
dc.format.extent2860157 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isospaen_US
dc.language.isoengen_US
dc.publisherConsejo Superior de Investigaciones Científicas (España)en_US
dc.rightsopenAccessen_US
dc.subjectImplantes metálicosen_US
dc.subjectHuesoen_US
dc.subjectRespuesta localen_US
dc.subjectRatasen_US
dc.subjectIn vivo testen_US
dc.subjectMetallic implantsen_US
dc.subjectBoneen_US
dc.subjectLocal responseen_US
dc.subjectRatsen_US
dc.titleRepuesta ósea local en ratas a implantes metálicos en función del tiempo de implantación.en_US
dc.title.alternativeLocal bone response in rats to metallic implants at different times of implantation.en_US
dc.typeArtículoen_US
dc.identifier.doi10.3989/revmetalm.2008.v44.i3.115-
dc.description.peerreviewedPeer revieweden_US
dc.relation.publisherversionhttp://dx.doi.org/10.3989/revmetalm.2008.v44.i3.115en_US
dc.identifier.e-issn1988-4222-
Appears in Collections:(CENIM) Artículos
Files in This Item:
File Description SizeFormat 
116.pdf2,79 MBAdobe PDFThumbnail
View/Open
Show simple item record
 


WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.