Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/140988
COMPARTIR / EXPORTAR:
logo share SHARE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorPeille, Philippe-
dc.contributor.authorWilms, Jörn-
dc.contributor.authorBrand, T.-
dc.contributor.authorCobo, Beatriz-
dc.contributor.authorCeballos, María Teresa-
dc.contributor.authorDauser, T.-
dc.contributor.authorSmith, S.-
dc.contributor.authorHerder, J. W. den-
dc.contributor.authorBarcons, Xavier-
dc.contributor.authorPointecouteau, E.-
dc.contributor.authorBandler, S.-
dc.date.accessioned2016-11-30T11:53:32Z-
dc.date.available2016-11-30T11:53:32Z-
dc.date.issued2015-
dc.identifier.citationExploring the Hot and Energetic Universe (2015)-
dc.identifier.urihttp://hdl.handle.net/10261/140988-
dc.descriptionTrabajo presentado a la Conferencia: Exploring the Hot and Energetic Universe: The first scientific conference dedicated to the Athena X-ray observatory; celebrada en Madrid (España) del 8 a 10 de septiembre de 2015.-- et al.-
dc.description.abstractThe focal plane assembly of the Athena X-ray Integral Field Unit (X-IFU) includes as the baseline an array of ~4000 single size calorimeters based on Transition Edge Sensors (TES). Other sensor array configurations could however be considered, combining TES of different properties (e.g. size). In attempting to improve the X-IFU performance in terms of field of view, count rate performance, and even spectral resolution, two alternative TES array configurations to the baseline have been simulated, each combining a small and a large pixel array. With the X-IFU end-to-end simulator, a sub-sample of the Athena core science goals, selected by the X-IFU science team as potentially driving the optimal TES array configuration, has been simulated for the results to be scientifically assessed and compared. In this contribution, we will describe the simulation set-up for the various array configurations, and highlight some of the results of the test cases simulated.-
dc.relation.isversionofPublisher's version-
dc.rightsopenAccess-
dc.titleThe X-IFU end-to-end simulations performed for the TES array optimization exercise-
dc.typepóster de congreso-
dc.date.updated2016-11-30T11:53:32Z-
dc.description.versionPeer Reviewed-
dc.language.rfc3066eng-
dc.relation.csic-
dc.type.coarhttp://purl.org/coar/resource_type/c_6670es_ES
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextWith Fulltext-
item.cerifentitytypePublications-
item.openairetypepóster de congreso-
item.grantfulltextopen-
Aparece en las colecciones: (IFCA) Comunicaciones congresos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato
TESarray.pdf8,3 MBAdobe PDFVista previa
Visualizar/Abrir
Show simple item record

CORE Recommender

Page view(s)

196
checked on 17-abr-2024

Download(s)

71
checked on 17-abr-2024

Google ScholarTM

Check


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.