English   español  
Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/14034
Compartir / Impacto:
Estadísticas
Add this article to your Mendeley library MendeleyBASE
Citado 11 veces en Web of Knowledge®  |  Pub MebCentral Ver citas en PubMed Central  |  Ver citas en Google académico
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Título

Research and development of a new RF-assisted device for bloodless rapid transection of the liver: Computational modeling and in vivo experiments

AutorBurdío, Fernando; Berjano, Enrique J.; Navarro, Ana; Burdío, José M.; Grande, Luis; Subirá, Jorge; Castiella, Tomás; Poves, Ignasi; Lequerica, Juan L.
Palabras claveRF
Assisted device
Transection
Fecha de publicación18-mar-2009
EditorBioMed Central
CitaciónBioMedical Engineering OnLine 2009, 8:6
Resumen[Background] Efficient and safe transection of biological tissue in liver surgery is strongly dependent on the ability to address both parenchymal division and hemostasis simultaneously. In addition to the conventional clamp crushing or finger fracture methods other techniques based on radiofrequency (RF) currents have been extensively employed to reduce intraoperative blood loss. In this paper we present our broad research plan for a new RF-assisted device for bloodless, rapid resection of the liver.
[Methods] Our research plan includes computer modeling and in vivo studies. Computer modeling was based on the Finite Element Method (FEM) and allowed us to estimate the distribution of electrical power deposited in the tissue, along with assessing the effect of the characteristics of the device on the temperature profiles. Studies based on in vivo pig liver models provided a comparison of the performance of the new device with other techniques (saline-linked technology) currently employed in clinical practice. Finally, the plan includes a pilot clinical trial, in which both the new device and the accessory equipment are seen to comply with all safety requirements.
[Results] The FEM results showed a high electrical gradient around the tip of the blade, responsible for the maximal increase of temperature at that point, where temperature reached 100°C in only 3.85 s. Other hot points with lower temperatures were located at the proximal edge of the device. Additional simulations with an electrically insulated blade produced more uniform and larger lesions (assessed as the 55°C isotherm) than the electrically conducting blade. The in vivo study, in turn, showed greater transection speed (3 ± 0 and 3 ± 1 cm2/min for the new device in the open and laparoscopic approaches respectively) and also lower blood loss (70 ± 74 and 26 ± 34 mL) during transection of the liver, as compared to saline-linked technology (2 ± 1 cm2/min with P = 0.002, and 527 ± 273 mL with P = 0.001).
Descripción10 pages, 8 figures, 2 tables and 1 additional file.
Versión del editorhttp://dx.doi.org/10.1186/1475-925X-8-6
URIhttp://hdl.handle.net/10261/14034
DOI10.1186/1475-925X-8-6
ISSN1475-925X
Aparece en las colecciones: (IBV) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
1475-925X-8-6.pdf1,21 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo
 



NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.