Título

A combined equation to estimate the soil pore-water electrical conductivity: Calibration with the WET and 5TE sensors

AutorVisconti Reluy, Fernando CSIC ORCID; Martínez, D. CSIC; Molina, M. J. CSIC; Ingelmo Sánchez, Florencio CSIC; Paz Bécares, José Miguel de
Palabras claveCapacitance
Sensor
Salinity
Irrigation
Frequency domain
Fecha de publicación26-jun-2014
EditorCSIRO Publishing
CitaciónAustralian Journal of Soil Research 52(5): 419-430 (2014)
ResumenAffordable, commercial dielectric sensors of the frequency domain reflectometry (FDR) and capacitance-conductance (CC) types estimate the dielectric permittivity (εb) and electrical conductivity (σb) of bulk soil. In this work, an equation was obtained to estimate the pore-water electrical conductivity (σp), which is closely related to the soil salinity in contact with plant roots, from εb and σb data, by combining the simplified dielectric mixing (SDM) model that relates εb to the soil volumetric water content (θ), with the Rhoades equation that relates θ and σb to σp. This equation was calibrated with measurements of εb and σb obtained with the Delta-T WET (FDR) and the Decagon 5TE (CC) sensors, in 20 pots filled with a clay loam soil and arranged as combinations of four levels of soil moisture with five levels of soil salinity. The calibrations were performed against reference θ and σp values. The σp was calculated with the chemical equilibrium model SALSOLCHEMEC and used as a more reliable reference than the electrical conductivity of the soil wetting water. For both sensors, the SDM model on the one hand, and the Rhoades equation on the other, provided the most accurate estimations using the least number of parameters regarding their respective alternatives, i.e. the third-order polynomial and the Hilhorst equation. The combined equation for estimation of σp subsequently provided root mean square deviations of 3.1 (WET) and 4.1 (5TE) dSm-1, which decreased to 1.5 and 2.6dSm-1 for θ >0.22m3 m-3, and σb <3 (WET) and 3.7 (5TE) dSm-1. A new combined equation has been proposed for reliable estimations of σp with these sensors in clayey soils for θ >0.22m3 m-3 and σb <3.7dSm-1. © CSIRO 2014.
Versión del editorhttps://doi.org/10.1071/SR13331
URIhttp://hdl.handle.net/10261/140163
DOI10.1071/SR13331
ISSN1838-675X
Aparece en las colecciones: (CIDE) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

14
checked on 20-abr-2024

WEB OF SCIENCETM
Citations

12
checked on 19-feb-2024

Page view(s)

304
checked on 24-abr-2024

Download(s)

170
checked on 24-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.