Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/137529
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Optimizing polymer lab-on-chip platforms for ultrasonic manipulation: Influence of the substrate

AutorGonzález, Itziar; Tijero Serna, María; Martin, Alain; Acosta, Víctor CSIC; Berganzo Ruiz, Javier; Castillejo, Adela; Bouali, Mounir M.; Soto, José Luis
Palabras clavePolymeric resonators
Ultrasonic manipulation
Lab-on-chip
Acoustic tweezers
Particle enrichment
Particle separation
Structure-fluid interactions
Microfluidics
Fecha de publicación7-may-2015
EditorMultidisciplinary Digital Publishing Institute
CitaciónMicromachines 6: 574-591 (2015)
ResumenThe choice of substrate material in a chip that combines ultrasound with microfluidics for handling biological and synthetic microparticles can have a profound effect on the performance of the device. This is due to the high surface-to-volume ratio that exists within such small structures and acquires particular relevance in polymer-based resonators with 3D standing waves. This paper presents three chips developed to perform particle flow-through separation by ultrasound based on a polymeric SU-8 layer containing channelization over three different substrates: Polymethyl methacrylate (PMMA); Pyrex; and a cracked PMMA composite-like structure. Through direct observations of polystyrene microbeads inside the channel, the three checked chips exhibit their potential as disposable continuous concentration devices with different spatial pressure patterns at frequencies of resonance close to 1 Mhz. Chips with Pyrex and cracked PMMA substrates show restrictions on the number of pressure nodes established in the channel associated with the inhibition of 3D modes in the solid structure. The glass-substrate chip presents some advantages associated with lower energy requirements to collect particles. According to the results, the use of polymer-based chips with rigid substrates can be advantageous for applications that require short treatment times (clinical tests handling human samples) and low-cost fabrication. © 2015 by the authors; licensee MDPI, Basel, Switzerland.
Versión del editorhttp://dx.doi.org/10.3390/mi6050574
URIhttp://hdl.handle.net/10261/137529
DOI10.3390/mi6050574
Identificadoresissn: 2072-666X
Aparece en las colecciones: (ITEFI) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
micromachines-06-00574.pdf3,33 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

15
checked on 13-abr-2024

WEB OF SCIENCETM
Citations

14
checked on 29-feb-2024

Page view(s)

230
checked on 18-abr-2024

Download(s)

313
checked on 18-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


Este item está licenciado bajo una Licencia Creative Commons Creative Commons