Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/135755
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

The impact of sensitive KIT D816V detection on recognition of Indolent Systemic Mastocytosis

AutorMatteis, Giovanna de; Zanotti, Roberta; García-Montero, Andrés CSIC ORCID
Palabras claveSystemic mastocytosis
Sequencing
D-HPLC
Real time PCR
D816V
KIT
Fecha de publicación2015
EditorElsevier
CitaciónLeukemia Research 39(3): 273-278 (2015)
ResumenPatients with Systemic Mastocytosis (SM) need a highly sensitive diagnostic test for D816V detection of the KIT receptor gene.Along with histology/cytology and flow cytometry evaluation, bone marrow (BM) from 110 consecutive adult patients referred with a suspicion of SM to Multidisciplinary Outpatient Clinic for Mastocytosis in Verona were tested both by Amplification Refractory Mutation System Reverse Transcriptase quantitative real time Polymerase Chain Reaction (ARMS-RT-qPCR) and RT-PCR. +. Restriction Fragment Length Polymorphism (RFLP) followed by Denaturing-High Performance Liquid Chromatography (D-HPLC) and Sanger sequencing.ARMS-RT-qPCR identified D816V mutation in 77 patients, corresponding to 100% of cases showing CD25+ mast cells (MCs) whereas RT-PCR+RFLP/D-HPLC+sequencing revealed D816V mutations in 47 patients.According to the 2008 WHO criteria 75 SM, 1 Cutaneous Mastocytosis (CM), 1 monoclonal MC activation syndrome (MMAS), and 1 SM Associated with Haematologic Non-Mast Cell Disorder (SM-AHNMD) were diagnosed. Seventeen out 75 SM patients (23%) would have not satisfied sufficient WHO criteria on the basis of the sole RT-PCR+RFLP: these patients had significantly lower serum tryptase levels and amount of CD25+ MCs.Therefore, ARMS-RT-qPCR might result particularly useful, in patients that do not fulfil major BM histological criterion, for the recognition of indolent SM with a very low MC burden.
URIhttp://hdl.handle.net/10261/135755
DOI10.1016/j.leukres.2014.11.029
Identificadoresdoi: 10.1016/j.leukres.2014.11.029
e-issn: 1873-5835
issn: 0145-2126
Aparece en las colecciones: (IBMCC) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

21
checked on 13-abr-2024

WEB OF SCIENCETM
Citations

18
checked on 23-feb-2024

Page view(s)

194
checked on 15-abr-2024

Download(s)

129
checked on 15-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.