Upgrade of goniospectrophtometer GEFE for near-field scattering and fluorescence radiance measurements

AutorBernad, Berta ; Ferrero, Alejandro ; Pons Aglio, Alicia ; Campos Acosta, Joaquín ; Hernanz, María Luisa
Fecha de publicación13-mar-2015
EditorSociety of Photo-Optical Instrumentation Engineers
CitaciónProceedings of SPIE - The International Society for Optical Engineering 9398: 93980E (2015)
ResumenThe goniospectrophotometer GEFE, designed and developed at IO–CSIC (Instituto de Optica, Agencia Estatal Consejo Superior de Investigaciones Cientificas), was conceived to measure the spectral Bidirectional Reflectance Distribution Function (BRDF) at any pair of irradiation and detection directions. Although the potential of this instrument has largely been proved, it still required to be upgraded to deal with some important scattering features for the assessment of the appearance. Since it was not provided with a detector with spatial resolution, it simply could not measure spectrophotometric quantities to characterize texture through the Bidirectional Texture Function (BTF) or translucency through the more complex Bidirectional Scattering–Surface Reflectance Distribution Function (BSSRDF). Another requirement in the GEFE upgrading was to provide it with the capability of measuring fluorescence at different geometries, since some of the new pigments used in industry are fluorescent, which can have a non–negligible impact in the color of the product. Then, spectral resolution at irradiation and detection had to be available in GEFE. This paper describes the upgrading of the goniospectrophotometer GEFE, and its new capabilities through the presentation of sparkle and goniofluorescence measurements. In addition, the potential of the instrument to evaluate translucency by the measurement of the BSSRDF is briefly discussed. © SPIE
Descripción11 págs.
Versión del editorhttp://dx.doi.org/10.1117/12.2077084
URIhttp://hdl.handle.net/10261/134953
DOI10.1117/12.2077084
Identificadoresdoi: 10.1117/12.2077084
issn: 0277-786X
Aparece en las colecciones: (CFMAC-IO) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo
 

Artículos relacionados:


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.