Thermal conductivity measurements of high and low thermal conductivity films using a scanning hot probe method in the 3ω mode and novel calibration strategies

AutorWilson, Adam Andrew; Muñoz Rojo, Miguel ; Abad Mayor, Begoña ; Pérez Taborda, Jaime Andrés; Maiz, Jon; Schomacker, Jason; Martín-González, Marisol S. ; Borca Tasciuc, Diana-Andra; Borca Tasciuc, Theodorian
Fecha de publicación2015
EditorRoyal Society of Chemistry (Great Britain)
CitaciónNanoscale 7: 15404-15412 (2015)
ResumenThis work discusses measurement of thermal conductivity (k) of films using a scanning hot probe method in the 3ω mode and investigates the calibration of thermal contact parameters, specifically the thermal contact resistance (RthC) and thermal exchange radius (b) using reference samples with different thermal conductivities. RthC and b were found to have constant values (with b = 2.8 ± 0.3 μm and Rthc = 44 927 ± 7820 K W−1) for samples with thermal conductivity values ranging from 0.36 W K−1 m−1 to 1.1 W K−1 m−1. An independent strategy for the calibration of contact parameters was developed and validated for samples in this range of thermal conductivity, using a reference sample with a previously measured Seebeck coefficient and thermal conductivity. The results were found to agree with the calibration performed using multiple samples of known thermal conductivity between 0.36 and 1.1 W K−1 m−1. However, for samples in the range between 16.2 W K−1 m−1 and 53.7 W K−1 m−1, calibration experiments showed the contact parameters to have considerably different values: Rthc = 40 191 ± 1532 K W−1 and b = 428 ± 24 nm. Finally, this work demonstrates that using these calibration procedures, measurements of both highly conductive and thermally insulating films on substrates can be performed, as the measured values obtained were within 1–20% (for low k) and 5–31% (for high k) of independent measurements and/or literature reports. Thermal conductivity results are presented for a SiGe film on a glass substrate, Te film on a glass substrate, polymer films (doped with Fe nano-particles and undoped) on a glass substrate, and Au film on a Si substrate. © 2015 The Royal Society of Chemistry.
Versión del editorhttp://dx.doi.org/10.1039/c5nr03274a
URIhttp://hdl.handle.net/10261/132200
DOI10.1039/c5nr03274a
Identificadoresissn: 2040-3372
Aparece en las colecciones: (IMN-CNM) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo
 

Artículos relacionados:


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.