An In-Line photonic biosensor for monitoring of glucose concentrations

AuthorsAl-Halhouli, Ala'aldeen; Demming, Stefanie; Alahmad, Laila; Llobera, Andreu CSIC ORCID; Büttgenbach, Stephanus
Keywordsbeads
immobilization
enzymes
glucose
Biosensors
Issue Date25-Aug-2014
PublisherMolecular Diversity Preservation International
CitationSensors 14(9): 15749-15759 (2014)
AbstractThis paper presents two PDMS photonic biosensor designs that can be used for continuous monitoring of glucose concentrations. The first design, the internally immobilized sensor, consists of a reactor chamber, micro-lenses and self-alignment structures for fiber optics positioning. This sensor design allows optical detection of glucose concentrations under continuous glucose flow conditions of 33 μL/h based on internal co-immobilization of glucose oxidase (GOX) and horseradish peroxidase (HRP) on the internal PDMS surface of the reactor chamber. For this design, two co-immobilization methods, the simple adsorption and the covalent binding (PEG) methods were tested. Experiments showed successful results when using the covalent binding (PEG) method, where glucose concentrations up to 5 mM with a coefficient of determination (R2) of 0.99 and a limit of detection of 0.26 mM are detectable. The second design is a modified version of the internally immobilized sensor, where a microbead chamber and a beads filling channel are integrated into the sensor. This modification enabled external co-immobilization of enzymes covalently onto functionalized silica microbeads and allows binding a huge amount of HRP and GOX enzymes on the microbeads surfaces which increases the interaction area between immobilized enzymes and the analyte. This has a positive effect on the amount and rate of chemical reactions taking place inside the chamber. The sensor was tested under continuous glucose flow conditions and was found to be able to detect glucose concentrations up to 10 mM with R2 of 0.98 and a limit of detection of 0.7 mM. Such results are very promising for the application in photonic LOC systems used for online analysis © 2014 by the authors; licensee MDPI, Basel, Switzerland.
Publisher version (URL)http://dx.doi.org/10.3390/s140915749
URIhttp://hdl.handle.net/10261/130908
DOI10.3390/s140915749
Identifiersissn: 1424-8220
Appears in Collections:(IMB-CNM) Artículos




Files in This Item:
File Description SizeFormat
Photonic_Biosensor_Al-Halhouli.pdf864,33 kBAdobe PDFThumbnail
View/Open
Show full item record
Review this work

PubMed Central
Citations

5
checked on Jan 2, 2023

SCOPUSTM   
Citations

11
checked on Jan 25, 2023

WEB OF SCIENCETM
Citations

12
checked on Jan 24, 2023

Page view(s)

196
checked on Jan 27, 2023

Download(s)

215
checked on Jan 27, 2023

Google ScholarTM

Check

Altmetric

Altmetric


Related articles:


WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.