Título: | Fast and simultaneous determination of endocrine disrupting compounds by ultra-high performance liquid chromatography-tandem mass spectrometry |
Autor: | Esteve, C. CSIC; Herrero, Laura CSIC ORCID; Gómara, Belén CSIC ORCID ; Quintanilla-López, Jesús Eduardo CSIC ORCID | Palabras clave: | Phthalates Parabens Bisphenol A Experimental design Ultra-high performance liquid chromatography Triple quadrupole tandem mass spectrometry Multicomponent method |
Fecha de publicación: | 2016 | Editor: | Elsevier | Citación: | Talanta 146: 326-334 (2016) | Resumen: | A rapid and sensitive analytical method for the simultaneous determination of thirteen endocrine disruptors (five phthalates, seven parabens, and bisphenol A) in a single chromatographic run has been developed for the first time. The separation method, based on ultra-high performance liquid chromatography (UHPLC), allows the separation of all compounds (including isobaric pairs) in less than 4.1 min. The fast polarity switching mode of the triple quadrupole mass spectrometer used enables the registration of positive (phthalates) and negative (parabens and BPA) ions in the same acquisition run. A Response Surface Methodology was used for the optimization of the method. The optimum elution program starts with 0.2 min in isocratic conditions (79.8% water; 20% acetonitrile, 0.2% ammonium formate 5 mM at pH 10.2), then the content of acetonitrile is linearly increased in 2 min up to 42%, and later up to 98% in 1.1 min. The analytical characteristics of the developed method were satisfactory. The method is robust and showed a linear response with determination coefficients (R<sup>2</sup>) higher than 0.991 in the range 5.0-2000 pg on column (or higher) for all the compounds investigated. Instrumental intra- and inter-day precision (expressed as relative standard deviation) were lower than 12% for parabens and bisphenol A, and between 5.9% and 27% for phthalates. Instrumental detection and quantification limits (iLODs and iLOQs) were in the range of medium-high femtograms (270-1300 pg on column for iLODs). Finally, the suitability of the developed method was demonstrated through its application to the analysis of commercial personal care products (shower gels) without any sample treatment, only a simple dilution, being possible to determine the simultaneous presence of phthalates, parabens, and bisphenol A in almost all the gels analyzed. | Versión del editor: | http://dx.doi.org/10.1016/j.talanta.2015.08.064 | URI: | http://hdl.handle.net/10261/127787 | DOI: | 10.1016/j.talanta.2015.08.064 | Identificadores: | doi: 10.1016/j.talanta.2015.08.064 issn: 0039-9140 e-issn: 1873-3573 |
Aparece en las colecciones: | (IQF) Artículos (IQOG) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
accesoRestringido.pdf | 15,38 kB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
SCOPUSTM
Citations
30
checked on 21-abr-2024
WEB OF SCIENCETM
Citations
31
checked on 28-feb-2024
Page view(s)
289
checked on 24-abr-2024
Download(s)
156
checked on 24-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.