Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/123395
COMPARTIR / EXPORTAR:
logo share SHARE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorGarcía López, J.-
dc.contributor.authorJiménez-Ramos, M. C.-
dc.date.accessioned2015-10-15T10:42:03Z-
dc.date.available2015-10-15T10:42:03Z-
dc.date.issued2014-
dc.identifier.citationICNMTA 2014-
dc.identifier.urihttp://hdl.handle.net/10261/123395-
dc.descriptionResumen del póster presentado a la "14th International Conference on Nuclear Microprobe Technology and Applications" celebrada en Padova (Italia) del 6 al 11 de julio de 2014.-
dc.description.abstractThe study of radiation effects in semiconductor electronics and detectors is fundamental to evaluate the lifetime and performance deterioration of the semiconductor devices working in high radiation environments like nuclear reactors, particle accelerators and outer space. In this work, we present a comparative study of the charge collection efficiency (CCE) degradation on a series of Si (n-type and p-type) and SiC (n-type) diodes after irradation with high energy protons. The CCE was determined by the Ion Beam Induced Charge (IBIC) technique using 4 MeV protons. Moreover, the transient behaviour of the collected carriers was analyzed at various reverse bias voltages. The diodes were irradiated in our cyclotron with 17 MeV protons and fluences ranging from 3-3*1011 to 3*1014 p/cm2. At this energy the proton stopping power across the samples is practically constant, leading to a uniform vacancy profile with depth. From the analysis of the IBIC results, using the simple drift-diffusion model, the change in the diffusion length of the minority carriers has been evaluated for different proton fluences. In addition, it has been observed an increase of the leakage current with ion dose, from which the damage coefficient of the samples has been calculated.-
dc.rightsclosedAccess-
dc.titleComparative study of the charge collection efficiency decrease on Si and SiC diodes after irradiation with high energy protons-
dc.typepóster de congreso-
dc.date.updated2015-10-15T10:42:03Z-
dc.description.versionPeer Reviewed-
dc.language.rfc3066eng-
dc.relation.csic-
dc.type.coarhttp://purl.org/coar/resource_type/c_6670es_ES
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.cerifentitytypePublications-
item.openairetypepóster de congreso-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
Aparece en las colecciones: (CNA) Comunicaciones congresos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Show simple item record

CORE Recommender

Page view(s)

179
checked on 24-abr-2024

Download(s)

36
checked on 24-abr-2024

Google ScholarTM

Check


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.