Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/118167
COMPARTIR / EXPORTAR:
SHARE CORE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Astrain, D.el | - |
dc.contributor.author | Vian, J. G. | - |
dc.contributor.author | Dominguez, Manuel | - |
dc.date.accessioned | 2015-07-20T09:35:06Z | - |
dc.date.available | 2015-07-20T09:35:06Z | - |
dc.date.issued | 2003 | - |
dc.identifier | doi: 10.1016/S1359-4311(03)00202-3 | - |
dc.identifier | issn: 1359-4311 | - |
dc.identifier.citation | Applied Thermal Engineering 23: 2183- 2200 (2003) | - |
dc.identifier.uri | http://hdl.handle.net/10261/118167 | - |
dc.description.abstract | A device for the dissipation the heat from the hot side of Peltier pellets in thermoelectric refrigeration, based on the principle of a thermosyphon with phase change is presented. The device design was accomplished by analytic calculations on the base of a semi-empirical formulation and simulations with computational fluids dynamics. In the experimental optimization phase, a prototype of thermosyphon with a thermal resistance of 0.110 K/W has been development, dissipating the heat of a Peltier pellet with the size of 40 × 40 mm, what is an improvement of 36% in the thermal resistance, with regard to the commercial fin dissipater. With the construction of the two prototypes of thermoelectric domestic refrigerators, one of them with the device developed, and the other with a conventional fins dissipater, it could be experimentally proved that the use of thermosyphon with phase change increases the coefficient of performance up to 32%. © 2003 Elsevier Ltd. All rights reserved. | - |
dc.publisher | Elsevier | - |
dc.rights | closedAccess | - |
dc.subject | COP | - |
dc.subject | Thermosyphon | - |
dc.subject | Peltier | - |
dc.subject | Heat dissipation | - |
dc.subject | Refrigeration | - |
dc.subject | Thermoelectricity | - |
dc.title | Increase of COP in the thermoelectric refrigeration by the optimization of heat dissipation | - |
dc.type | artículo | - |
dc.identifier.doi | 10.1016/S1359-4311(03)00202-3 | - |
dc.date.updated | 2015-07-20T09:35:06Z | - |
dc.description.version | Peer Reviewed | - |
dc.language.rfc3066 | eng | - |
dc.type.coar | http://purl.org/coar/resource_type/c_6501 | es_ES |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | none | - |
item.openairetype | artículo | - |
Aparece en las colecciones: | (IF) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
accesoRestringido.pdf | 15,38 kB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
SCOPUSTM
Citations
106
checked on 22-abr-2024
WEB OF SCIENCETM
Citations
90
checked on 22-feb-2024
Page view(s)
262
checked on 24-abr-2024
Download(s)
160
checked on 24-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.