Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/116451
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorGómez, Rodrigo-
dc.contributor.authorIvorra Cano, Antoni-
dc.contributor.authorVilla, Rosa-
dc.contributor.authorGodignon, Philippe-
dc.contributor.authorMillán, José-
dc.contributor.authorErill, Iván-
dc.contributor.authorSolà, Anna M.-
dc.contributor.authorHotter, Georgina-
dc.contributor.authorPalacios, Luis-
dc.date.accessioned2015-06-11T11:52:30Z-
dc.date.available2015-06-11T11:52:30Z-
dc.date.issued2006-03-
dc.identifierdoi: 10.1007/s10544-006-6381-y-
dc.identifierissn: 1387-2176-
dc.identifier.citationBiomedical Microdevices 8(1): 43-49 (2006)-
dc.identifier.urihttp://hdl.handle.net/10261/116451-
dc.description.abstractMonitoring of ischemia in living tissues is a field of increasing interest in many clinical settings. In this work we report for the first time anywhere the development of needle-shaped, minimally-invasive impedance probes based on silicon carbide (SiC) substrates. An in-vitro comparison of these new devices with Si-based impedance probes demonstrates that their effective operation range extends up to the 100 kHz range, thus allowing a wide-spectrum multi-frequency analysis of impedance modulus and phase angle. Furthermore, we show that, when applied to in-vivo settings, this kind of analysis yields to an accurate monitoring of ischemia, while making possible the application of more robust mathematical methods for the study of impedance in living tissues. © Springer Science + Business Media, Inc. 2006.-
dc.description.sponsorshipThis work was supported by the REF2004450F022 grant from the Consejo Superior de Investigaciones Científicas-
dc.publisherKluwer Academic Publishers-
dc.rightsclosedAccess-
dc.subjectIschemia-
dc.subjectProbe-
dc.subjectSilicon carbide-
dc.subjectImpedance-
dc.titleA SiC microdevice for the minimally invasive monitoring of ischemia in living tissues-
dc.typeartículo-
dc.identifier.doi10.1007/s10544-006-6381-y-
dc.relation.publisherversionhttp://dx.doi.org/10.1007/s10544-006-6381-y-
dc.date.updated2015-06-11T11:52:30Z-
dc.description.versionPeer Reviewed-
dc.language.rfc3066eng-
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es_ES
item.openairetypeartículo-
item.grantfulltextnone-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextNo Fulltext-
Aparece en las colecciones: (IMB-CNM) Artículos
(IIBB) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Show simple item record

CORE Recommender

SCOPUSTM   
Citations

22
checked on 18-abr-2024

WEB OF SCIENCETM
Citations

16
checked on 29-feb-2024

Page view(s)

261
checked on 18-abr-2024

Download(s)

88
checked on 18-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.