Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/11543
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Evaluation of a newly developed enzyme-linked immunosorbent assay for determination of linear alkyl benzenesulfonates in wastewater treatment plants

AutorFarré, Marinella CSIC ORCID; Ramón-Azcón, Javier CSIC ORCID; Galvé, Roger CSIC ORCID ; Marco, María Pilar CSIC ORCID CVN ; Barceló, Damià CSIC ORCID
Palabras claveWastewater control analysis
Enzime-linked
Immunosorbent assay
Linear alkyl
Benzenesulfonates (LAS)
Sulfophenyl carboxylates (SPCs)
Fecha de publicación19-jul-2006
EditorAmerican Chemical Society
CitaciónEnvironmental Science & Technology 40(16): 5064-5070 (2006)
ResumenA recently developed enzyme-linked immunosorbent assay (ELISA) for the determination of linear alkyl benzenesulfonates (LAS) and long chain sulfophenyl carboxylates (SPCs) has been evaluated for its application in wastewater control analysis. This ELISA based on the use of polyclonal antibodies in an indirect format shows an IC50 of 28.1 ± 3.2 μg L-1 and a limit of detection (LOD) of 1.8 ± 0.6 μg L-1 in buffer. The assay uses antibodies raised through a pseudoheterologous immunization strategy using an equimolar mixture of two immunogens, N-(4-alkylphenyl)sulfonyl-3-aminopropanoic acid covalently coupled to keyhole limped hemocyanin (SFA-KLH) and sulfophenyl carboxylate 13C13 coupled to KLH (13C13-SPC-KLH). The immunizing haptens have been designed to address recognition versus two different epitopes of the LAS molecule. To assess the performance of this immunoassay in complex real samples, a cross reactivity study was carried out, and the possible interference of other surfactants commonly detected in wastewater, including nonylphenol ethoxylates (NPEOs), nonylphenol (NP), octylphenol (OP), and coconut fatty acid diethanol amides (CDEA), have been evaluated. Additionally, a study of the matrix effects of different types of wastewater was achieved. This ELISA has been evaluated and validated by measuring the LAS content of 22 samples collected from the influents and the effluents of six wastewater treatment plants (WWTP) located in Catalonia, Spain. A solid-phase extraction followed by liquid chromatography coupled to mass spectrometry detection (SPE-LC-MS) has been used as a validation method of the new ELISA test.
Descripción7 pages, 5 figures, 2 tables.-- PMID: 16955908 [PubMed].-- Printed version published Aug 15, 2006.
Versión del editorhttp://dx.doi.org/10.1021/es060662
URIhttp://hdl.handle.net/10261/11543
DOI10.1021/es060662
ISSN0013-936x
E-ISSN1520-5851
Aparece en las colecciones: (IDAEA) Artículos
(IQAC) Artículos

Mostrar el registro completo

CORE Recommender

Page view(s)

352
checked on 18-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.