English   español  
Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/11459
Compartir / Impacto:
Estadísticas
Add this article to your Mendeley library MendeleyBASE
Citado 12 veces en Web of Knowledge®  |  Ver citas en Google académico
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Título

Feasibility of high-performance immunochromatography as an isolation method for PCBs and other dioxin-like compounds

AutorConcejero, Miguel A. ; Galvé, Roger; Herradón García, Bernardo ; González, M. Jesús ; Frutos, Mercedes de
Fecha de publicación16-may-2001
EditorAmerican Chemical Society
CitaciónAnalytical Chemistry 73(13): 3119-3125 (2001)
ResumenA high performance immunochromatographic procedure to isolate polychlorinated biphenyls (PCBs) and other dioxin-like compounds from a sample is shown. Development of the procedure includes (i) synthesis of the hapten, binding it to the spacer arm and to the carrier protein to make the immunizing molecule; (ii) raising and purification of anti-PCB antibodies; (iii) building of the immunocolumn; (iv) selection of the binding, rinsing, and elution conditions adequate for these highly lipophilic compounds; (v) study of the influence of the concentration and volume of sample on recovery; and (vi) study of the selectivity of the immunosystem for dioxins, furans, PCBs, and several insecticides of different toxicity. Evaluation of the method is carried out by analyzing the fractions retained and nonretained in the immunocolumn by GC/MS. The immunochromatographic system that is developed shows itself to be feasible as cleanup and isolation steps carried out prior to GC/MS analyses. When compared to classical cleanup and isolation methods traditionally used for analysis of PCBs in water, the immunochromatographic method is >20× faster and uses 100× less organic solvents, and its selectivity is enormously enhanced. Good recoveries are obtained with both kinds of methods. The immunochromatographic procedure fulfils the acceptance criteria indicated by the EPA, even for sub-parts-per-billion concentrations.
Descripción7 pages, 3 figures, 3 tables.-- PMID: 11467562 [PubMed].-- Printed version published on Jul 1, 2001.
Part of this work in included in Spanish patent P200001313, http://digital.csic.es/handle/10261/11427
Versión del editorhttp://dx.doi.org/10.1021/ac001387r
URIhttp://hdl.handle.net/10261/11459
DOI10.1021/ac001387r
ISSN0003-2700
Aparece en las colecciones: (IQOG) Artículos
(IQAC) Artículos
Ficheros en este ítem:
No hay ficheros asociados a este ítem.
Mostrar el registro completo
 



NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.