English   español  
Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/111034
Compartir / Impacto:
Estadísticas
Add this article to your Mendeley library MendeleyBASE
Citado 6 veces en Web of Knowledge®  |  Pub MebCentral Ver citas en PubMed Central  |  Ver citas en Google académico
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Exportar otros formatos: Exportar EndNote (RIS)Exportar EndNote (RIS)Exportar EndNote (RIS)
Título

Antibody generation and immunoassay development in diverse formats for pyrimethanil specific and sensitive analysis

Autor Mercader Badia, Josep Vicent ; Esteve Turrillas, Francesc A. ; Agulló, Consuelo; Abad Somovilla, Antonio; Abad Fuentes, Antonio
Palabras clave Fungicides
Immunoassay
ELISA
Pyrimethanil
Haptens
Antibodies
Fecha de publicación 2012
EditorRoyal Society of Chemistry (Great Britain)
Citación The Analyst 137: 5672- 5679 (2012)
ResumenImmunochemical techniques are complementary tools to modern analytical requirements. These methods rely on the production of immunoreagents with adequate binding properties. In the present study, a rationally designed and functionalized derivative of pyrimethanil-a modern anilinopyrimidine fungicide-was synthesized in order to generate for the first time high-affinity and selective antibodies to this xenobiotic. A single coupling procedure-based on hapten activation using N,N′-disuccinimidyl carbonate and purification of the active ester-was followed to prepare both immunizing and assay conjugates. Polyclonal antibodies were produced and characterized by enzyme-linked immunosorbent assay (ELISA) in four alternative formats: one indirect and three direct competitive procedures. The selected immunoassay displayed a limit of detection of 0.024 μg L-1, far lower than the official maximum residue limits and close to the sensitivity of regular instrumental assays. This ELISA was shown to be robust to buffer changes and tolerant to the presence of little amounts of methanol, ethanol and acetonitrile. Finally, the developed assay was applied to the analysis of pyrimethanil in carrot juice samples, and a limit of quantification of 0.040 mg L-1 was determined.
URI http://hdl.handle.net/10261/111034
DOI10.1039/c2an35801h
Identificadoresdoi: 10.1039/c2an35801h
issn: 0003-2654
Aparece en las colecciones: (IATA) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Analyst-2012-Mercader.pdf349,23 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo
 



NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.