Title

The performance of the CMS muon detector in proton-proton collisions at√s = 7 TeV at the LHC

AuthorsChatrchyan, S.; Brochero Cifuentes, J. A. ; Cabrillo, I. J. ; Cabrillo, I. J. ; Cabrillo, I. J. ; Calderon, Alicia ; Chuang, S. H. ; Duarte Campderros, J. ; Felcini, Marta ; Fernández, M. ; Gómez, G. ; González Sánchez, J. ; Graziano, A. ; Jorda, C. ; López Virto, A. ; Marco, Jesús ; Marco, Rafael ; Martínez-Rivero, Celso ; Martínez-Rivero, Celso ; Matorras, Francisco ; Muñoz Sánchez, F. J. ; Rodrigo, Teresa ; Rodríguez Marrero, Ana Y. ; Ruiz Jimeno, Alberto ; Scodellaro, Luca ; Vila, Iván ; Vilar, Rocío ; CMS Collaboration
Issue Date2013
PublisherInstitute of Physics Publishing
CitationJournal of Instrumentation 8: P11002 (2013)
AbstractThe performance of all subsystems of the CMS muon detector has been studied by using a sample of proton-proton collision data at √s = 7 TeV collected at the LHC in 2010 that corresponds to an integrated luminosity of approximately 40 pb-1. The measured distributions of the major operational parameters of the drift tube (DT), cathode strip chamber (CSC), and resistive plate chamber (RPC) systems met the design specifications. The spatial resolution per chamber was 80–120 μm in the DTs, 40–150 μm in the CSCs, and 0.8–1.2 cm in the RPCs. The time resolution achievable was 3 ns or better per chamber for all 3 systems. The efficiency for reconstructing hits and track segments originating from muons traversing the muon chambers was in the range 95–98%. The CSC and DT systems provided muon track segments for the CMS trigger with over 96% efficiency, and identified the correct triggering bunch crossing in over 99.5% of such events. The measured performance is well reproduced by Monte Carlo simulation of the muon system down to the level of individual channel response. The results confirm the high efficiency of the muon system, the robustness of the design against hardware failures, and its effectiveness in the discrimination of backgrounds.
DescriptionPublished under the terms of the Creative Commons Attribution 3.0 licence.-- et al.
Publisher version (URL)http://dx.doi.org/10.1088/1748-0221/8/11/P11002
URIhttp://hdl.handle.net/10261/109978
DOI10.1088/1748-0221/8/11/P11002
Identifiersdoi: 10.1088/1748-0221/8/11/P11002
e-issn: 1748-0221
Appears in Collections:(IFCA) Artículos
Files in This Item:
File Description SizeFormat 
performance of the CMS muon detector.pdf8,65 MBAdobe PDFThumbnail
View/Open
Show full item record
Review this work
 

Related articles:


WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.