Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Castro-Puyana, M. | - |
dc.contributor.author | Herrero, Laura | - |
dc.contributor.author | González, M. Jesús | - |
dc.contributor.author | Gómara, Belén | - |
dc.date.accessioned | 2014-10-23T10:38:15Z | - |
dc.date.available | 2014-10-23T10:38:15Z | - |
dc.date.issued | 2013 | - |
dc.identifier | doi: 10.1016/j.aca.2013.05.045 | - |
dc.identifier | issn: 0003-2670 | - |
dc.identifier | e-issn: 1873-4324 | - |
dc.identifier.citation | Analytica Chimica Acta 787: 148- 154 (2013) | - |
dc.identifier.uri | http://hdl.handle.net/10261/103748 | - |
dc.description.abstract | Instrumental methods based on gas chromatography coupled to mass spectrometry (GC-MS) have been developed and compared using two different MS ionisation modes, electron impact (EI) and electron capture negative ionisation (ECNI), for the fast, quantitative and simultaneous determination of polychlorinated biphenyls (PCBs) and their main metabolites (hydroxylated PCBs, OH-PCBs, and methyl sulfone PCBs, MeSO2-PCBs). Parameters affecting chromatographic separation and MS detection were evaluated in order to achieve the highest selectivity and sensitivity for both operation modes. The analytical characteristics of the developed methods were studied and compared in terms of linear range, limits of detection (LODs), limits of quantification (LOQs), and instrumental precision (repeatability and intermediate precision). Both ionisation methods showed similar precision, being relative standard deviations (RSD, %) lower than 9% and 14% for repeatability and intermediate precision, respectively. However, better LODs (from 0.01 to 0.14pg injected for the three families of congeners studied) were achieved using ECNI-MS as ionisation mode. The suitability of the developed method was demonstrated through their application to fish liver oil samples. | - |
dc.publisher | Elsevier | - |
dc.rights | closedAccess | - |
dc.subject | Mass spectrometry | - |
dc.subject | Gas chromatography | - |
dc.subject | Electron capture negative ionisation | - |
dc.subject | Electron impact | - |
dc.subject | Metabolites | - |
dc.subject | Polychlorinated biphenyls | - |
dc.title | Rapid and simultaneous determination of polychlorinated biphenyls and their main metabolites (hydroxylated and methyl sulfonyl) by gas chromatography coupled to mass spectrometry: Comparison of different ionisation modes | - |
dc.type | artículo | - |
dc.identifier.doi | 10.1016/j.aca.2013.05.045 | - |
dc.date.updated | 2014-10-23T10:38:16Z | - |
dc.description.version | Peer Reviewed | - |
dc.language.rfc3066 | eng | - |
dc.type.coar | http://purl.org/coar/resource_type/c_6501 | es_ES |
item.openairetype | artículo | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | none | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | No Fulltext | - |
Aparece en las colecciones: | (IQOG) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
accesoRestringido.pdf | 15,38 kB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
SCOPUSTM
Citations
1
checked on 27-mar-2024
WEB OF SCIENCETM
Citations
2
checked on 21-feb-2024
Page view(s)
301
checked on 27-mar-2024
Download(s)
88
checked on 27-mar-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.