Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/103748
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorCastro-Puyana, M.-
dc.contributor.authorHerrero, Laura-
dc.contributor.authorGonzález, M. Jesús-
dc.contributor.authorGómara, Belén-
dc.date.accessioned2014-10-23T10:38:15Z-
dc.date.available2014-10-23T10:38:15Z-
dc.date.issued2013-
dc.identifierdoi: 10.1016/j.aca.2013.05.045-
dc.identifierissn: 0003-2670-
dc.identifiere-issn: 1873-4324-
dc.identifier.citationAnalytica Chimica Acta 787: 148- 154 (2013)-
dc.identifier.urihttp://hdl.handle.net/10261/103748-
dc.description.abstractInstrumental methods based on gas chromatography coupled to mass spectrometry (GC-MS) have been developed and compared using two different MS ionisation modes, electron impact (EI) and electron capture negative ionisation (ECNI), for the fast, quantitative and simultaneous determination of polychlorinated biphenyls (PCBs) and their main metabolites (hydroxylated PCBs, OH-PCBs, and methyl sulfone PCBs, MeSO2-PCBs). Parameters affecting chromatographic separation and MS detection were evaluated in order to achieve the highest selectivity and sensitivity for both operation modes. The analytical characteristics of the developed methods were studied and compared in terms of linear range, limits of detection (LODs), limits of quantification (LOQs), and instrumental precision (repeatability and intermediate precision). Both ionisation methods showed similar precision, being relative standard deviations (RSD, %) lower than 9% and 14% for repeatability and intermediate precision, respectively. However, better LODs (from 0.01 to 0.14pg injected for the three families of congeners studied) were achieved using ECNI-MS as ionisation mode. The suitability of the developed method was demonstrated through their application to fish liver oil samples.-
dc.publisherElsevier-
dc.rightsclosedAccess-
dc.subjectMass spectrometry-
dc.subjectGas chromatography-
dc.subjectElectron capture negative ionisation-
dc.subjectElectron impact-
dc.subjectMetabolites-
dc.subjectPolychlorinated biphenyls-
dc.titleRapid and simultaneous determination of polychlorinated biphenyls and their main metabolites (hydroxylated and methyl sulfonyl) by gas chromatography coupled to mass spectrometry: Comparison of different ionisation modes-
dc.typeartículo-
dc.identifier.doi10.1016/j.aca.2013.05.045-
dc.date.updated2014-10-23T10:38:16Z-
dc.description.versionPeer Reviewed-
dc.language.rfc3066eng-
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es_ES
item.openairetypeartículo-
item.cerifentitytypePublications-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextNo Fulltext-
Aparece en las colecciones: (IQOG) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Show simple item record

CORE Recommender

SCOPUSTM   
Citations

1
checked on 27-mar-2024

WEB OF SCIENCETM
Citations

2
checked on 21-feb-2024

Page view(s)

301
checked on 27-mar-2024

Download(s)

88
checked on 27-mar-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.